A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Outcomes of radiofrequency ablation by manual versus self-sizing circumferential balloon catheters for the treatment of dysplastic Barrett's esophagus: a multicenter comparative cohort study. | LitMetric

Background And Aims: Radiofrequency ablation (RFA) is the preferred ablative modality for treating dysplastic Barrett's esophagus. The recently introduced self-sizing circumferential ablation catheter eliminates the need for a sizing balloon. Although it enhances efficiency, outcomes have not been compared with the previous manual-sizing catheter. We evaluated the comparative safety and efficacy of these 2 ablation systems in a large, multicenter cohort.

Methods: Patients undergoing RFA at 3 tertiary care centers from 2005 to 2018 were included. Circumferential RFA was performed in a standard fashion, followed by focal RFA as needed. Outcomes were compared between the self-sizing and manual-sizing groups. The primary outcome was the rate of adverse events, including strictures, perforation, and bleeding. Secondary outcomes were procedure time and treatment efficacy, as assessed by rates and time to complete eradication of dysplasia (CE-D) and intestinal metaplasia (CE-IM).

Results: Three hundred eighteen patients were included, 90 (28.3%) treated with the self-sizing catheter and 228 (71.7%) with the manual-sizing catheter. Twenty-one patients (6.6%) developed strictures (8 [8.9%] in the self-sizing group and 13 [5.7%] in the manual-sizing group, P = .32). Of the self-sizing strictures, 75% occurred at the 12J dose before widespread adoption of the current 10J treatment standard. One patient developed bleeding, and no perforations were encountered. Procedure time was significantly shorter in the self-sizing group. No significant differences were observed in rates of and time to CE-D and CE-IM.

Conclusions: These findings suggest that both systems are comparable in safety and efficacy. The use of the self-sizing system may enhance the efficiency of RFA for treating dysplastic Barrett's esophagus.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2020.07.056DOI Listing

Publication Analysis

Top Keywords

dysplastic barrett's
12
barrett's esophagus
12
radiofrequency ablation
8
self-sizing
8
self-sizing circumferential
8
treating dysplastic
8
outcomes compared
8
manual-sizing catheter
8
safety efficacy
8
procedure time
8