A reliable animal model of corneal stromal opacity: Development and validation using in vivo imaging.

Ocul Surf

The Cornea Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India; Center for Ocular Regeneration (CORE), LV Prasad Eye Institute, Hyderabad, Telangana, India; Brien Holden Eye Research Centre, LV Prasad Eye Institute, Hyderabad, Telangana, India. Electronic address:

Published: October 2020

Purpose: To validate an animal model of corneal stromal opacity by using objective vision-independent in vivo imaging metrics.

Methods: This was a prospective study, with two arms: (i) observational human arm which included 14 patients with healed unilateral ulcerative keratitis; and (ii) experimental rabbit arm, which included 6 New Zealand white rabbits. A 3-mm central wound was created in the left eye of the rabbits by manually removing 200-250 μm of the superficial stroma, followed by rotating-burr application. Both groups underwent photography, high-resolution anterior segment optical coherence tomography, and Scheimpflug imaging using similar diagnostic platforms and standardized image capturing protocols. Parameters studied were relative change in (i) corneal thickness; (ii) corneal epithelial: stromal (E:S) reflectivity ratio; (iii) corneal stromal light scattering using densitometry; and (iv) central corneal keratometry.

Results: In the experimental arm, there was a significant decrease in corneal thickness (273 ± 51.3 vs. 407.3 ± 10.3 μm, p = 0.0038), E:S reflectivity ratio (0.71 ± 0.09 vs. 0.99 ± 0.06, p = 0.0018), and keratometry (40.4 ± 2.3 vs. 45.8 ± 0.9D, p = 0.0033) and increase in densitometry (54.2 ± 11.65 vs.18.7 ± 3.8 GSU, p = 0.0001) from baseline, which stabilized at 4 to 8-weeks post-wounding (p > 0.3632). At 8-weeks, the relative change from baseline in corneal thickness (28.4 ± 13.5% vs.22.4 ± 13%, p = 0.368), E:S reflectivity ratio (28.1 ± 11.5% vs. 30.6 ± 8.9%, p = 0.603), corneal densitometry (204.17 ± 97.3% vs. 304.9 ± 113.6%, p = 0.1113), and central corneal keratometry (13.6 ± 6.9% vs. 18.9 ± 7.4%, p = 0.1738) in rabbits was similar to human corneal scars.

Conclusion: The animal model of corneal opacification was objectively comparable to human post-keratitis scars and can be valuable for in vivo evaluation of emerging therapies for corneal opacities.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtos.2020.07.017DOI Listing

Publication Analysis

Top Keywords

corneal
13
animal model
12
model corneal
12
corneal stromal
12
corneal thickness
12
reflectivity ratio
12
stromal opacity
8
vivo imaging
8
arm included
8
relative change
8

Similar Publications

Nano-alkaline ion-excited NETs ablative eye drops promote ocular surface recovery.

J Control Release

December 2024

Department of Ophthalmology, Changzhou Third Peopls's Hospital, Changzhou Clinical College of Xuzhou Medical University, 300 Lanlin North road, Changzhou, Jiangsu 213000, China. Electronic address:

Neutrophil extracellular traps (NETs) promote neovascularization during the acute phase after ocular chemical injury, while the local inflammatory acidic environment delays post-injury repair. Currently, the mechanism of NETs promoting neovascularization has not been fully elucidated, and there is a lack of therapeutic strategies to effectively improve the local microenvironment for corneal repair. In this study, we validated the NETs-M2-angiogenic pathway after injury.

View Article and Find Full Text PDF

Background: To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods: Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery.

View Article and Find Full Text PDF

The burden of medical contraindications to corneal donation: Time for review.

PLOS Glob Public Health

December 2024

Laboratory Biology, Engineering and Imaging for Ophthalmology, Health Innovation Campus, Faculty of Medicine, University Jean Monnet, Saint-Etienne, France.

Corneal graft (keratoplasty) is the most common allograft in the world, but the imbalance between the number of donors and the number of patients waiting for transplants is abysmal on a global scale and varies enormously from one country to another. The risk of transmission of systemic diseases from donor to recipient is demonstrably low. In over 50 years and an estimated 2.

View Article and Find Full Text PDF

Purpose: To assess the ability of the Dolphin air-pulse aesthesiometer to present multiple stimuli, which are separated temporally (in sequence) or spatially (simultaneously).

Methods: Two studies were performed to explore the cooling effects induced by double air-puff stimuli generated by a novel aesthesiometer composed of two micro-blower integrated units. The stimuli were delivered sequentially or simultaneously at the same or different spatial locations to an in vitro eye model monitored using thermography.

View Article and Find Full Text PDF

Pregnancy with Wilson's Disease: A Case Series.

Mymensingh Med J

January 2025

Dr Mousumi Saha, Assistant Professor, Fetomaternal Medicine Subspeciality (FCPS) Course Student, Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh; E-mail:

Wilson's disease is an autosomal recessive disorder that affects copper transport due to deficiency of ceruloplasmin and causes deposition of copper mainly in the liver, brain and cornea. It causes hepatic and/or neuropsychiatric manifestations. This copper deposition causes cirrhosis of the liver, encephalopathy and liver failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!