Osteoarthritis in cats is more prevalent because cats are living longer with advancement in veterinary medicine. Objective evaluation of behavioral changes in cats with osteoarthritis can facilitate an early diagnosis. The objective of this study was to investigate the utility of a novel activity monitor for analyzing physical activities and sleep quality in cats. First, a novel activity monitor (Plus Cycle®; JARMeC, Kanagawa, Japan), with a built-in three-directional accelerometer and an air pressure sensor specifically designed for cats, was compared to a human activity monitor (Actical®; Philips Respironics, OR, USA) previously used in cats (n = 10). Second, the validity of the measurement accuracy of the amount of physical activity, the number of vibrations, the number of jumps, and the resting and sleeping time was evaluated using Plus Cycle® in healthy cats (n = 6). Finally, the effects of gender and age of cats and time of day on the amount of physical activity, the number of vibrations, the number of jumps, and the resting and sleeping time were investigated in client-owned cats (n = 61). There were strong correlations between Plus Cycle® and Actical® in total activity (p < 0.05) and activity intensity (p < 0.05). When the physical activities were measured using Plus Cycle® in healthy cats, those data were quantified with high accuracy. In addition, it was also found to be very accurate in discriminating the resting and sleeping conditions of cats. In client-owned cats, there were no significant differences with respect to gender in any measured traits. The amount of physical activity and the number of jumps significantly decreased with the age of the cat. In contrast, the resting and sleeping times significantly increased with the age of the cat. In conclusion, Plus Cycle® can accurately and objectively assess physical activities and sleep quality with age of the cat, suggesting that this novel activity monitor can be used to manage the feline musculoskeletal health.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7394395 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0236795 | PLOS |
Environ Sci Pollut Res Int
January 2025
School of Natural and Built Environment, Queen's University Belfast, Belfast, Northern Ireland, BT7 1NN, UK.
This research presents a straightforward and economically efficient design for a microbial fuel cell (MFC) that can be conveniently integrated into a borehole to monitor natural attenuation in groundwater. The design employs conventional, transparent, and reusable PVC bailers with graphite tape and granular activated carbon to create high surface area electrodes. These electrodes are connected across redox environments in nested boreholes through a wire and variable resistor setup.
View Article and Find Full Text PDFCell
December 2024
Key Laboratory Experimental Teratology of the Ministry of Education, New Cornerstone Science Laboratory, Department of Biochemistry and Molecular Biology, School of Basic Medical Sciences, Shandong University, Jinan, Shandong 250012, China; NHC Key Laboratory of Otorhinolaryngology, Qilu Hospital of Shandong University, Advanced Medical Research Institute, Shandong University, Jinan, China; Department of Physiology and Pathophysiology, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing, China. Electronic address:
Animals have evolved pH-sensing membrane receptors, such as G-protein-coupled receptor 4 (GPR4), to monitor pH changes related to their physiology and generate adaptive reactions. However, the evolutionary trajectory and structural mechanism of proton sensing by GPR4 remain unresolved. Here, we observed a positive correlation between the optimal pH of GPR4 activity and the blood pH range across different species.
View Article and Find Full Text PDFRheumatology (Oxford)
January 2025
Department of Rheumatology, Acute Rheumatology Centre Rhineland-Palatinate, Bad Kreuznach, Germany.
Objective: To examine the longitudinal associations of optical spectral transmission (OST) with clinical inflammatory arthritis activity markers in order to investigate its potential in monitoring disease activity.
Methods: OST measurements were performed in 1,312 wrist and finger joints of 60 patients with clinical suspicion of inflammatory activity, within the context of known rheumatic inflammatory diseases at two separate time intervals. In each time point, patients underwent additional clinical and laboratory examinations.
Alzheimers Dement
December 2024
Douglas Research Centre/ McGill University, Montreal, QC, Canada.
Background: Altered neuronal timing and synchrony are biomarkers for Alzheimer's disease (AD) and correlate with memory impairments. Electrical stimulation of the fornix, the main fibre bundle connecting the hippocampus to the septum, has emerged as a potential intervention to restore network synchrony and memory performance in human AD and mouse models. However, electrical stimulation is non-specific and may partially explain why fornix stimulation in AD patients has yielded mixed results.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
UK Dementia Research Institute at the University of Edinburgh, Edinburgh, Scotland, United Kingdom.
Background: Alzheimer's disease (AD) is the primary cause of dementia, characterized by early amyloid beta accumulation, subsequent tau pathology, and eventually synaptic and neuronal loss. Sleep disturbances, a clinical phenotype in AD, are linked to amyloid beta and impaired protein clearance. However, the influence of tau pathology on sleep is less explored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!