Enhancing the Accuracy of Vertical Ground Reaction Force Measurement During Walking Using Pressure-Measuring Insoles.

J Biomech Eng

École Supérieure d'Électronique de l'Ouest, 10 Boulevard Jean Jeanneteau, Angers 49100, France; Commission des Titres d'Ingenieur (CTI), 44 Rue Cambronne, Paris 75015, France.

Published: January 2021

Pressure-measuring insoles can be an attractive tool for measuring ground reaction force (GRF) since they are portable and can record multiple consecutive steps. Several researchers have, however, observed that these insoles are less accurate than instrumented force platforms. To address this issue, the authors identified transfer functions that best described each insole size to enhance the measurements of the vertical component of GRF during walking. GRF data were collected from 29 participants (6/23 male/female, 24.3 ± 6.7 yrs, 70.4 ± 23.9 kg, 1.66 ± 0.11 m) using Medilogic® pressure-measuring insoles and Kistler® force platforms for three walking trials. Participants provided the institutionally approved written consent (IRB #724468). The data from both instruments were preprocessed. A subset of the data was used to train the system identification toolbox (matlab) to identify the coefficients of several candidate transfer functions for each insole size. The resulting transfer functions were compared using all available data for each insole to assess which one modified the insole data to be closer to that of the force platform. All tested transfer functions moved the vertical component of GRF closer to the corresponding force platform data. Each insole size had a specific transfer model that that yielded the best results. Using system identification techniques produced transfer functions that, when using insole data of the vertical component of GRF as input, produced output that is comparable to the corresponding measurement using an instrumented force platform.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.4047993DOI Listing

Publication Analysis

Top Keywords

transfer functions
20
pressure-measuring insoles
12
insole size
12
vertical component
12
component grf
12
force platform
12
ground reaction
8
reaction force
8
instrumented force
8
force platforms
8

Similar Publications

CAFs-released exosomal CREB1 promotes cell progression and immune evasion in thyroid cancer via the positive regulation of CCL20.

Autoimmunity

December 2025

Department of Thyroid Head and Neck Surgery, The Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China.

Background: Exosomes derived from cancer-associated fibroblasts (CAFs) can affect tumor microenvironment (TME) of thyroid cancer (TC). The cAMP response element binding protein 1 (CREB1) acts as a transcription factor to participate in cancer development. Currently, we aimed to explore the molecular mechanism of exosome-associated CREB1 and C-C motif chemokine ligand 20 (CCL20) in TC.

View Article and Find Full Text PDF

Physical unclonable in-memory computing for simultaneous protecting private data and deep learning models.

Nat Commun

January 2025

Beijing Advanced Innovation Center for Integrated Circuits, School of Integrated Circuits, Peking University, Beijing, China.

Compute-in-memory based on resistive random-access memory has emerged as a promising technology for accelerating neural networks on edge devices. It can reduce frequent data transfers and improve energy efficiency. However, the nonvolatile nature of resistive memory raises concerns that stored weights can be easily extracted during computation.

View Article and Find Full Text PDF

An ultrasensitive ECL immunosensor with a dual signal amplification strategy using AuNPs@GO@SmMoSe and Gd(MoO) for estriol detection.

Anal Chim Acta

February 2025

School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea. Electronic address:

Background: Estriol (E3) is a common estrogen responsible for regulating the female reproductive system, but excessive amount can pose health risks to humans and wild life. Therefore, sensitive and accurate detection of estriol level is crucial. A novel competitive ECL immunosensor based on a dual signal amplification strategy of AuNPs@GO@SmMoSe and Gd(MoO) was fabricated for ultrasensitive detection of estriol.

View Article and Find Full Text PDF

The application of spermatogonial stem cells (SSC) will be more effective and feasible following the successful cryopreservation and transfer of SSCs in livestock. Like other cells, SSCs are also sensitive to cryoinjury; hence composition of the cryomedia and freezing protocols need to be optimized. The present study aims to optimising the best freezing rates by minimising the ice crystallization and dehydration effect in order to maximize the post-thaw SSCs survivability and stemness characteristics.

View Article and Find Full Text PDF

Two-in-one strategy to enhance the stability of TiCT in transition metal ion solutions.

J Colloid Interface Sci

January 2025

College of Materials Science and Engineering, Hunan University, Changsha 410082 PR China. Electronic address:

Although MXenes have attracted significant attention across diverse fields, they exhibit a pronounced susceptibility to oxidation in aqueous environments, with oxidation significantly accelerated in the presence of transition metal ions (TMI) such as Fe and Cu. This limitation impedes the synthesis of transition metal compounds/MXene-based composites and their potential for functional applications. In this study, we elucidate the mechanism of accelerated oxidation of TiCT is that Fe promotes the electron loss in TiCT, thus leading to an increased production of hydroxyl radicals (OH) to oxidize TiCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!