Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Computational fluid dynamics (CFD) has become a popular tool for studying 'patient-specific' blood flow dynamics in cerebral aneurysms; however, rarely are the inflow boundary conditions patient-specific. We aimed to test the impact of widespread reliance on generalized inflow rates.
Methods: Internal carotid artery (ICA) flow rates were measured via 2D cine phase-contrast MRI for 24 patients scheduled for endovascular therapy of an ICA aneurysm. CFD models were constructed from 3D rotational angiography, and pulsatile inflow rates imposed as measured by MRI or estimated using an average older-adult ICA flow waveform shape scaled by a cycle-average flow rate (Q) derived from the patient's ICA cross-sectional area via an assumed inlet velocity.
Results: There was good overall qualitative agreement in the magnitudes and spatial distributions of time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and spectral power index (SPI) using generalized versus patient-specific inflows. Sac-averaged quantities showed moderate to good correlations: R=0.54 (TAWSS), 0.80 (OSI), and 0.68 (SPI). Using patient-specific Q to scale the generalized waveform shape resulted in near-perfect agreement for TAWSS, and reduced bias, but not scatter, for SPI. Patient-specific waveform had an impact only on OSI correlations, which improved to R=0.93.
Conclusions: Aneurysm CFD demonstrates the ability to stratify cases by nominal hemodynamic 'risk' factors when employing an age- and vascular-territory-specific recipe for generalized inflow rates. Q has a greater influence than waveform shape, suggesting some improvement could be achieved by including measurement of patient-specific Q into aneurysm imaging protocols.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/neurintsurg-2020-015993 | DOI Listing |