A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Update of the simplified criteria for autoimmune hepatitis: Evaluation of the methodology for immunoserological testing. | LitMetric

Background & Aims: The simplified criteria for the diagnosis of autoimmune hepatitis (AIH) include immunofluorescence testing (IFT) of antinuclear and smooth muscle autoantibodies (ANA and SMA) on rodent tissue sections. We aimed to establish scoring criteria for the implementation of ANA IFT on human epithelioma-2 (HEp-2) cells and ELISA-based testing.

Methods: ANA and SMA reactivity of 61 AIH sera and 72 non-alcoholic fatty liver disease controls were separately assessed on tissue sections and HEp-2 cells to compare the diagnostic value at increasing titers. A total of 113 patients with AIH at diagnosis and 202 controls from 3 European centers were assessed by IFT as well as 3 different commercially available ANA ELISA and 1 anti-F-actin ELISA.

Results: ANA assessment by IFT on liver sections had 83.6% sensitivity and 69.4% specificity for AIH at a titer of 1:40. On HEp-2 cells, sensitivity and specificity were 75.4% and 73.6%, respectively, at an adjusted titer of 1:160. Area under the curve (AUC) values of ANA ELISA ranged from 0.70-0.87, with ELISA coated with HEp-2 extracts in addition to selected antigens performing significantly better. SMA assessment by IFT had the highest specificity for the SMA-VG/T pattern and anti-microfilament reactivity on HEp-2 cells. ELISA-based anti-F-actin evaluation was a strong predictor of AIH (AUC 0.88) and performed better than SMA assessment by IFT (AUC 0.77-0.87).

Conclusion: At adjusted cut-offs, both ANA IFT using HEp-2 cells and ELISA-based autoantibody evaluation for ANA and SMA are potential alternatives to tissue-based IFT for the diagnosis of AIH.

Lay Summary: Autoantibodies are a hallmark of autoimmune hepatitis and are traditionally tested for by immunofluorescence assays on rodent tissue sections. Herein, we demonstrate that human epithelioma cells can be used as a reliable substrate for immunofluorescence testing. ELISA-based testing is also a potentially reliable alternative for autoantibody assessment in autoimmune hepatitis. We propose the implementation of these testing methods into the simplified criteria for the diagnosis of autoimmune hepatitis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhep.2020.07.032DOI Listing

Publication Analysis

Top Keywords

autoimmune hepatitis
20
hep-2 cells
20
simplified criteria
12
ana sma
12
tissue sections
12
cells elisa-based
12
assessment ift
12
criteria diagnosis
8
diagnosis autoimmune
8
immunofluorescence testing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!