Truncated aptamers as selective receptors in a gluten sensor supporting direct measurement in a deep eutectic solvent.

Biosens Bioelectron

Departamento de Química Física y Analítica, Universidad de Oviedo, Av. Julián Clavería 8, 33006, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias, Av. de Roma, 33011, Oviedo, Spain. Electronic address:

Published: October 2020

AI Article Synopsis

  • Enzyme-linked immunosorbent assays (ELISAs) are commonly used to measure gluten in foods, but the antibodies in these tests struggle with traditional gluten extraction solvents.
  • A new electrochemical sensor has been developed using a specially designed 19-nucleotide DNA aptamer that effectively detects gliadin in a novel deep eutectic solvent called ethaline.
  • This sensor can quantify gluten levels as low as 20 μg/kg in food samples, making it a valuable tool for assessing gluten content and potential health risks for individuals with celiac disease or gluten sensitivities.

Article Abstract

Enzyme-linked immunosorbent assays are currently the most popular methods to quantify gluten in foods. Unfortunately, the antibodies used as specific receptors in such methods are not compatible with the usual solvents for the extraction of gluten proteins. In consequence, commercial tests require a high dilution of the sample after the extraction, increasing the limit of quantification and decreasing convenience. In this work, we have rationally truncated an aptamer capable of recognizing gliadin in a deep eutectic solvent (DES). The truncated aptamer is a 19-nucleotides-long DNA that minimizes self-hybridization, allowing the development of an electrochemical sandwich-based sensor for the quantification of gluten in the DES ethaline. The sensor incorporates two identical biotin-labeled truncated aptamers, one of which is immobilized on a carbon screen-printed electrode and the other reports the binding of gliadin after incubation in streptavidin-peroxidase. This sensor can detect gliadin in DES, with a dynamic range between 1 and 100 μg/L and an intra-assay coefficient of variation of 11%. This analytical performance allows the quantification of 20 μg of gluten/kg of food when 1 g of food is extracted with 10 mL of ethaline. We demonstrate the ability of this method to achieve the measurement of gluten in food samples, after the extraction with pure ethaline. The assay is useful for the analysis of residual gluten levels in foods, thus facilitating the evaluation of any potential health risk associated with the consumption of such food by people with celiac disease or other gluten-related disorders.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2020.112339DOI Listing

Publication Analysis

Top Keywords

truncated aptamers
8
deep eutectic
8
eutectic solvent
8
truncated aptamer
8
gluten
6
truncated
4
aptamers selective
4
selective receptors
4
receptors gluten
4
sensor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!