Purpose: To evaluate the role of combination of N-acetylcysteine with stepwise ramping voltage in renal protection against the ischemic, vascular and oxidative effects of extracorporeal shock wave lithotripsy.
Patients And Methods: A prospective randomized trial on 164 adult patients scheduled for ESWL for single renal stones. Patients with radio-lucent stones, diabetes, hypertension, febrile UTI, and preoperative albuminuria were excluded from the study. Patients were randomized into one of four groups. Group A patients received maximal fixed voltage of ESWL. Group B patients received stepwise ramping voltage of ESWL. Group C patients received fixed maximal voltage with N-acetylcysteine (NAC) 600 mg/bid from 48 h before to 24 h after the procedure. Group D patients received gradual ramping voltage with NAC. Urinary β-microglobulin, 24 h albumin and N-acetyl-β-D-glucosaminidase/creatinine ratio at 1 day and 5 days post-ESWL and the stone free rate at 2 weeks were measured.
Results: Group D was the only group that showed no significant difference pre and post ESWL in urinary albumin, β-microglobulin and N-acetyl-β-D-glucosaminidase/creatinine ratio. Post hoc analysis revealed no significant difference between group B and group C in albumin, β-microglobulin N-acetyl-β-D-glucosaminidase/creatinine ratio, but both of them had significantly lower levels than group A and significantly higher levels than group D. There was no statistically significant difference between all groups in the stone free rate at 2 weeks.
Conclusion: N-acetylcysteine protects the kidney against ESWL-induced renal injuries especially if combined with stepwise ramping voltage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11255-020-02580-1 | DOI Listing |
Heliyon
October 2024
Department of Computers and Information Technologies, College of Sciences and Arts Turaif, Northern Border University, Arar 91431, Saudi Arabia.
The Environmental Economic Power Dispatch (EEPD) problem, a widely studied bi-objective nonlinear optimization challenge in power systems, traditionally focuses on the economic dispatch of thermal generators without considering network security constraints. However, environmental sustainability necessitates reducing emissions and increasing the penetration of renewable energy sources (RES) into the electrical grid. The integration of high levels of RES, such as wind and solar PV, introduces stability issues due to their uncertain and intermittent nature.
View Article and Find Full Text PDFSensors (Basel)
November 2024
School of Microelectronics, Xidian University, Xi'an 710071, China.
In order to address the inconsistency problem caused by parasitic backend wiring among multiple ramp generators and among multiple columns in large-array CMOS image sensors (CIS), this paper proposes a high-precision compensation technology combining average voltage technology, adaptive negative feedback dynamic adjustment technology, and digital correlation double sampling technology to complete the design of an adaptive ramp signals inconsistency calibration scheme. The method proposed in this article has been successfully applied to a CIS with a pixel array of 8192(H) × 8192(V), based on the 55 nm 1P4M CMOS process, with a pixel size of 10×10μm2. The chip area is 88(H) × 89(V) mm2, and the frame rate is 10 fps.
View Article and Find Full Text PDFSci Rep
October 2024
International College of Semiconductor Technology, National Yang Ming Chiao Tung University, Hsinchu, 30010, Taiwan, ROC.
Adv Mater
December 2024
Materials Science and Engineering Program, Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955, Saudi Arabia.
Conductive atomic force microscopy (CAFM) analyzes electronic phenomena in materials and devices with nanoscale lateral resolution, and it is widely used by companies, research institutions, and universities. Most data published in the field of CAFM is collected in air at a relative humidity (RH) of 30-60%. However, the effect of RH in CAFM remains unclear because previous studies often made contradictory claims, plus the number of samples and locations tested is scarce.
View Article and Find Full Text PDFAnal Chem
September 2024
Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Leibniz Universität Hannover, Appelstr. 9A, Hannover 30167, Germany.
Besides safety and security applications, ion mobility spectrometry (IMS) is increasingly used in other fields such as medicine, environmental monitoring and food quality analysis. However, some applications require gas chromatographic separation before analysis by IMS. Furthermore, different compounds in the sample may form positive or negative ions during ionization and therefore simultaneous detection of both ion polarities is highly beneficial to avoid two chromatographic runs of the same sample.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!