A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adverse Events Related to Cartiva Hemiarthroplasty of First Metatarsal: An Analysis of Reports to the United States Food and Drug Administration. | LitMetric

The results supporting Cartiva, a synthetic cartilage implant (Wright Medical) in hallux rigidus have come from limited institutions creating observational bias. Complications experienced in community centers are not routinely included in the published literature. To look at a broader range of potential complications, we reviewed the United States Food and Drug Administration's (FDA) voluntary device database and compared that data with published literature. The Manufacturer and User Facility Device Experience (MAUDE) database of the FDA was retrospectively reviewed between July 2016 and October 2019 using the product code: PNW, assigned for Cartiva. A total of 49 events have been reported and implant subsidence was the most common with 16 reports. Others include fragmentation (9), infection (4), bone erosion (3), foreign body reaction (1) and unspecified (16). Thirty-five events mentioned further surgeries at a mean interval of 4.75 months. The analysis of the MAUDE database disclosed certain device-related dysfunctions that have been underreported in the published literature. Because of the voluntary nature of reporting, the true incidence of each complication is unknown with this data representing a baseline. The MAUDE database could be further strengthened by a more robust reporting mechanism or mandatory reporting of device-related complications. Level IV: Case series from large database analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1938640020943715DOI Listing

Publication Analysis

Top Keywords

published literature
12
maude database
12
united states
8
states food
8
food drug
8
database
5
adverse events
4
events cartiva
4
cartiva hemiarthroplasty
4
hemiarthroplasty metatarsal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!