A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic yield of the implantable loop recorder in octogenarians. | LitMetric

Background/objectives: Syncope in octogenarians represents an important problem in terms of comorbidity, quality of life and substantial medical costs, resulting from studies and treatments. An implantable loop ecorder (ILR) may improve diagnostic performance. The objective of the study was to evaluate the results of the ILR in a population of octogenarians.

Design: Prospective registry of patients receiving an implantable loop recorder in 40 Spanish centers.

Participants: 128 octogenarians implanted with a device for clinical evaluation of syncope.

Methods: Prospective registry recording the incidence of new symptoms or device activations within the first year after the implant, the incidence of new diagnosis and treatments, and an evaluation of the safety of this strategy in this population. Dedicated database for the registry.

Results: Forty-two patients (33% of the population) obtained a final etiological diagnosis of the syncope, which led to a specific treatment in 39 (31%) patients. No differences regarding the presence of conduction disturbances or structural heart disease were found in this population. A mortality of 4% was recorded during follow-up.

Conclusion: The implantable loop recorder seems to be an effective and safe tool in the management of syncope in the octogenarian population.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s41999-018-0128-1DOI Listing

Publication Analysis

Top Keywords

implantable loop
16
loop recorder
12
prospective registry
8
population
5
diagnostic yield
4
implantable
4
yield implantable
4
loop
4
recorder octogenarians
4
octogenarians background/objectives
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!