Introduction: Our aim was to assess the effect of introducing flash monitoring in adults with type 1 diabetes with respect to change in hemoglobin A1c (HbA1c) and frequency of hospital admissions.

Research Design And Methods: Prospective observational study of adults with type 1 diabetes in our center, in whom a prescription for a flash monitoring sensor was collected. Primary outcome was change in HbA1c between 2016 and after flash monitoring. Rates of hospital admission were compared between the first year after flash monitoring and the corresponding 12-month period 2 years earlier.

Results: Approximately half of all adults with type 1 diabetes, attending our center, collected prescriptions for flash monitoring sensors (n=2216). Median fall in HbA1c was -1 (-0.1) mmol/mol (%) (p<0.001) and was greatest in those with baseline HbA1c >75 (9.0) mmol/mol (%): -10 (-0.9) mmol/mol (%), p<0.001. 43% of those with a baseline HbA1c >53 mmol/mol (7%) experienced a ≥5 mmol/mol (0.5%) fall in HbA1c. In addition to higher HbA1c, early commencement within 1 month of NHS-funded flash monitoring (p<0.001), and male gender (p=0.013) were associated with a fall in HbA1c of ≥5 (0.5) mmol/mol (%). Socioeconomic deprivation (p=0.009) and collecting fewer than 2 sensors per month (p=0.002) were associated with lack of response. Overall, hospital admissions did not change but an increase in admissions for hypoglycemia was observed (1.1% vs 0.3%, p=0.026).

Conclusions: Flash monitoring is associated with reduction in HbA1c in individuals with HbA1c >58 mmol/mol. Numerous clinical features are independently associated with HbA1c response. An increase in hypoglycemia admissions occurred following flash monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7389509PMC
http://dx.doi.org/10.1136/bmjdrc-2020-001292DOI Listing

Publication Analysis

Top Keywords

flash monitoring
28
adults type
16
type diabetes
16
hba1c response
8
flash
8
monitoring
8
monitoring adults
8
fall hba1c
8
hba1c
7
response hospital
4

Similar Publications

Background: Compared to older adults with breast cancer (BC), adolescents and young adults (AYAs) develop more aggressive disease necessitating more intensive therapy with curative intent, which is disruptive to planned life trajectories. The burden of unmet needs among AYA BC survivors exists in two domains: (1) symptoms (e.g.

View Article and Find Full Text PDF

Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.

Langenbecks Arch Surg

January 2025

Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.

Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.

Methods: Thirty non-diabetic pancreatectomy patients participated.

View Article and Find Full Text PDF

Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus.

Diabetes Metab Syndr Obes

January 2025

Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210012, People's Republic of China.

Objective: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM).

Methods: This is a prospective observational study involving patients with T2DM aged ≥60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10.

View Article and Find Full Text PDF

Aims: This study assessed efficacy and safety of the fixed ratio combination iGlarLixi 100/33 (insulin glargine 100 U/mL plus lixisenatide 33 μg/mL) in people with type 2 diabetes (PwT2D) in daily clinical practice.

Materials And Methods: This non-interventional, multicentre, prospective, single-arm 24-week study documented PwT2D with an HbA1c of 7.5%-10.

View Article and Find Full Text PDF

Objective: This study compares ambulatory glycemic profile and glycemic variability between pregnant women diagnosed with type 2 diabetes mellitus (T2DM) receiving pharmacotherapy and healthy pregnant women without diabetes and assesses their correlation with fetal outcome.

Method: This was a case-control study involving 60 pregnant women (40 with T2DM and 20 healthy controls) in the third trimester of pregnancy. A flash glucose monitor device was applied over the upper arm to obtain the ambulatory glucose profile.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!