Major hemorrhage is often associated with trauma-induced coagulopathy. Targeted blood product replacement could achieve faster hemostasis and reduce mortality. This study aimed to investigate whether thromboelastography (TEG) goal-directed transfusion improved blood utilization, reduced mortality, and was cost effective. Data were prospectively collected in a U.K. level 1 trauma center, in patients with major hemorrhage one year pre- and post-implementation of TEG 6s Hemostasis Analyzers. Mortality, units of blood products transfused, and costs were compared between groups. Patient demographics in pre-TEG ( = 126) and post-TEG ( = 175) groups were similar. Mortality was significantly lower in the post-TEG group at 24 h (13% vs. 5%; = 0.006) and at 30 days (25% vs. 11%; = 0.002), with no difference in the number or ratio of blood products transfused. Cost of blood products transfused was comparable, with the exception of platelets (average £38 higher post-TEG). Blood product wastage was significantly lower in the post-TEG group (1.8 ± 2.1 vs. 1.1 ± 2.0; = 0.002). No statistically significant difference in cost was observed between the two groups (£753 ± 651 pre-TEG; £830 ± 847 post-TEG; = 0.41). These results demonstrate TEG 6s-driven resuscitation algorithms are associated with reduced mortality, reduced blood product wastage, and are cost neutral compared to standard coagulation tests.