AI Article Synopsis

Article Abstract

Point-of-care (POC) or near-patient testing allows clinicians to accurately achieve real-time diagnostic results performed at or near to the patient site. The outlook of POC devices is to provide quicker analyses that can lead to well-informed clinical decisions and hence improve the health of patients at the point-of-need. Microfluidics plays an important role in the development of POC devices. However, requirements of handling expertise, pumping systems and complex fluidic controls make the technology unaffordable to the current healthcare systems in the world. In recent years, capillary-driven flow microfluidics has emerged as an attractive microfluidic-based technology to overcome these limitations by offering robust, cost-effective and simple-to-operate devices. The internal wall of the microchannels can be pre-coated with reagents, and by merely dipping the device into the patient sample, the sample can be loaded into the microchannel driven by capillary forces and can be detected via handheld or smartphone-based detectors. The capabilities of capillary-driven flow devices have not been fully exploited in developing POC diagnostics, especially for antimicrobial resistance studies in clinical settings. The purpose of this review is to open up this field of microfluidics to the ever-expanding microfluidic-based scientific community.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7459612PMC
http://dx.doi.org/10.3390/diagnostics10080509DOI Listing

Publication Analysis

Top Keywords

capillary-driven flow
12
flow microfluidics
8
poc devices
8
microfluidics
4
microfluidics combined
4
combined smartphone
4
smartphone detection
4
detection emerging
4
emerging tool
4
tool point-of-care
4

Similar Publications

Trigger valves are fundamental features in capillary-driven microfluidic systems that stop fluid at an abrupt geometric expansion and release fluid when there is flow in an orthogonal channel connected to the valve. The concept was originally demonstrated in closed-channel capillary circuits. We show here that trigger valves can be successfully implemented in open channels.

View Article and Find Full Text PDF
Article Synopsis
  • Trigger valves are essential components in microfluidic systems that control fluid flow by stopping it at expansions and allowing release through connected channels.
  • This study successfully implements trigger valves in open channels and demonstrates how multiple valves can create layered capillary flow alongside main channels.
  • A model for flow dynamics at these valves was developed and validated, with implications for applications in biosensing, sample preparation, hydrogel patterning, and organ-on-a-chip technologies.
View Article and Find Full Text PDF

Controlling Drying Conditions in Vacuum for Uniform Film Formation in Inkjet-Printed OLEDs.

ACS Appl Mater Interfaces

October 2024

Autonomous Manufacturing & Process R&D Dept., Korea Institute of Industrial Technology (KITECH), Ansan-si, Gyeong-gi-do 15588, Republic of Korea.

The drying process of inkjet-printed organic light-emitting diodes (OLEDs) is influenced by both ink properties and external environmental factors, which ultimately affect the film profile. First, we conducted a detailed investigation of the drying time based on changes in the boiling point (BP) of mixed solvents and analyzed the correlation with the film profile. Under atmospheric drying conditions in a nitrogen (N) atmosphere, the increased drying time under capillary-driven flow leads to greater particle movement toward the edges, significantly increasing the coffee-ring effect.

View Article and Find Full Text PDF

Dynamics of salt precipitation at pore scale during CO subsurface storage in saline aquifer.

J Colloid Interface Sci

January 2025

Delft University of Technology, Department of Geoscience and Engineering, Stevinweg 1, 2628 CN Delft, the Netherlands; Shell Global Solutions International B.V., Grasweg 31, 1031 HW Amsterdam, the Netherlands.

CO storage in deep saline aquifers is an effective strategy for reducing greenhouse gas emission. However, salt precipitation triggered by evaporation of water into injected dry CO causes injectivity reduction. Predicting the distribution of precipitated salts and their impact on near-well permeability remains challenging.

View Article and Find Full Text PDF

Biomarkers and their concentration levels are critical indicators of metabolomics for clinical applications. Rapid and sensitive analysis methods are essential for realizing timely and efficient quantitation of those significant biomarkers. In this work, a self-driven microfluidic immunosensor was developed for rapid all-in-one separation, enrichment, and detection of biomarkers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!