We conducted a systematic review in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement to ascertain why polyurethanes (PUs) have been used in the manufacture and design of cardiovascular devices. A complete database search was performed with PubMed, Scopus, and Web of Science as the information sources. The search period ranged from 1 January 2005 to 31 December 2019. We recovered 1552 articles in the first stage. After the duplicate selection and extraction procedures, a total of 21 papers were included in the analysis. We concluded that polyurethanes are being applied in medical devices because they have the capability to tolerate contractile forces that originate during the cardiac cycle without undergoing plastic deformation or failure, and the capability to imitate the behaviors of different tissues. Studies have reported that polyurethanes cause severe problems when applied in blood-contacting devices that are implanted for long periods. However, the chemical compositions and surface characteristics of polyurethanes can be modified to improve their mechanical properties, blood compatibility, and endothelial cell adhesion, and to reduce their protein adhesion. These modifications enable the use of polyurethanes in the manufacture and design of cardiovascular devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7435973 | PMC |
http://dx.doi.org/10.3390/ma13153250 | DOI Listing |
J Neurol Surg Rep
January 2025
Department of Neurosurgery, Hospital of the German Armed Forces, Westerstede, Germany.
Although osteosarcomas are the most frequent primary malignant bone tumors, the primary cranial manifestation of this condition is very rare with only a limited number of cases presented in the literature. We present the case of a 20-year-old male patient who underwent single-session surgical intervention for resection of right frontal osteosarcoma with a tailor-made craniotomy and cranioplasty using virtually designed 3D-printed templates and molds. Subsequently, the patient was treated according to the EURAMOS protocol and received adjuvant systemic chemotherapy.
View Article and Find Full Text PDFRSC Adv
January 2025
Department of Electrical and Electronic Engineering, International Islamic University Chittagong Kumira Chittagong 4318 Bangladesh
Perovskite solar cells are commonly employed in photovoltaic systems because of their special characteristics. Perovskite solar cells remain efficient, but lead-based absorbers are dangerous, restricting their manufacture. Therefore, studies in the field of perovskite materials are now focusing on investigating lead-free perovskites.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Total hip arthroplasty (THA) is a very successful operation. Once the problem of implant fixation was solved with the use of bone cement, the next development steps focused on improving the bearing. Weber, a Swiss surgeon, introduced the first modular heads in THA.
View Article and Find Full Text PDFSci Rep
January 2025
National Clinical Research Center for Geriatrics, West China Hospital of Sichuan University, Chengdu, Sichuan Province, China.
This study aimed to develop a real-time, noninvasive hyperkalemia monitoring system for dialysis patients with chronic kidney disease. Hyperkalemia, common in dialysis patients, can lead to life-threatening arrhythmias or sudden death if untreated. Therefore, real-time monitoring of hyperkalemia in this population is crucial.
View Article and Find Full Text PDFOrg Lett
January 2025
Key Laboratory for Green Pharmaceutical Technologies and Related Equipment of Ministry of Education, College of Pharmaceutical Sciences, Zhejiang University of Technology, Hangzhou 310014, P. R. China.
Herein, a -phenylphenothiazine-based hyper-cross-linked polymer (PTH-HCP) was finely designed and constructed, which serves as a metal-free heterogeneous photocatalyst for organic transformations. Characterization experiments have shown that this polymer demonstrates outstanding stability, extensive surface area, and exceptional photoelectric response properties. Moreover, PTH-HCP showed good catalytic efficiency and recyclability in the photochemically driven difluoromethylation/cyclization reactions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!