How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?

J Clin Med

Department of Prosthodontics, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Geriatric Dentistry and Craniomandibular Disorders, 14197 Berlin, Germany.

Published: July 2020

3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of <1 mm, vertical discrepancies of <0.6 mm, and axial deviations of ≤3°. In the vertical dimension, no differences between the four groups were measured ( ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM ( ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured ( ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations ( = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463912PMC
http://dx.doi.org/10.3390/jcm9082322DOI Listing

Publication Analysis

Top Keywords

oral implant
12
surgical guides
12
implant placement
8
metal sleeves
8
sagittal transversal
8
implant
5
surgical
5
guides
5
accurate oral
4
implant installation
4

Similar Publications

Objective: This study aims to evaluate the clinical efficacy of electro-pneumatic intracorporeal lithotripsy for the treatment of salivary gland stones.

Study Design: A prospective cohort study of patients diagnosed with obstructive salivary gland syndrome, where basket-assisted sialendoscopy alone failed to remove the calculi.

Setting: This study was conducted at the "Queen Maria" Military Hospital in Brașov, Romania, and a private practice, between February 2023 and May 2024.

View Article and Find Full Text PDF

Background & Objective: Currently, there are many implants in clinical use, making it hard to choose the right one for the patient. The success rate of an implant depends on its diameter, length, and direction of insertion in bone. In implant dentistry, Finite Element Analysis (FEA) simulates intraoral conditions in vitro and analyzes the effects of implant material, diameter, size, and other components related to oral structure on the implant and peri-implant tissues.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation (TAVI) involves complex decisions regarding perioperative anticoagulation, with continuation or interruption of oral anticoagulation presenting distinct risks and benefits. This systematic review and meta-analysis compared the clinical outcomes of these two strategies during TAVI. We conducted a comprehensive literature search across multiple electronic databases, including PubMed, Embase, Cochrane Library, and Web of Science, from inception to November 2024.

View Article and Find Full Text PDF

Edentulous patients with history of cleft palate and severe maxillary atrophy are challenging patients to rehabilitate through an oral approach. The difficulty of rehabilitating these patients lies in the unusual anatomy they present and the alteration of the vascular supply of local tissues caused by the previous performed surgeries, along with other causes. This report describes the successful dental rehabilitation with zygomatic implants of a patient with complete bilateral cleft palate who was edentulous and had severe maxillary atrophy.

View Article and Find Full Text PDF

Objectives: Infantile hemangioma (IH) is a benign vascular tumor that occurs in 5% of infants, predominantly in female and preterm neonates. Propranolol is the mainstay of treatment for IH. Given the short half-life of propranolol regarding β-adrenergic receptor inhibition as well as its side effects, propranolol is administered to infants 2-3 times daily with 1 mg/kg/dose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!