On-site wastewater treatment plants (OSTs) are usually unattended, so failures often remain undetected and lead to prolonged periods of reduced performance. To stabilize the performance of unattended plants, soft sensors could expose faults and failures to the operator. In a previous study, we developed soft sensors and showed that soft sensors with data from unmaintained physical sensors can be as accurate as soft sensors with data from maintained ones. The monitored variables were pH and dissolved oxygen (DO), and soft sensors were used to predict nitrification performance. In the present study, we use synthetic data and monitor three plants to test these soft sensors. We find that a long solids retention time and a moderate aeration rate improve the pH soft-sensor accuracy and that the aeration regime is the main operational parameter affecting the accuracy of the DO soft sensor. We demonstrate that integrated design of monitoring and control is necessary to achieve robustness when extrapolating from one OST to another in the absence of plant-specific fine-tuning. Additionally, we provide a unique labeled dataset for further feature and data-driven soft-sensor development. Our benchmarking results indicate that it is feasible to monitor OSTs with unmaintained sensors and without plant-specific tuning of the developed soft sensors. This is expected to drastically reduce monitoring costs for OST-based sanitation systems.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.est.9b07760DOI Listing

Publication Analysis

Top Keywords

soft sensors
32
sensors
10
on-site wastewater
8
wastewater treatment
8
treatment plants
8
soft
8
developed soft
8
sensors data
8
benchmarking soft
4
sensors remote
4

Similar Publications

PEDOT/Polypyrrole Core-Sheath Fibers for Use as Conducting Polymer Artificial Muscles.

ACS Appl Mater Interfaces

January 2025

Sensor and Actuator Systems, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping SE-581 83, Sweden.

Electropolymerized polypyrrole (PPy) is considered as one of the promising polymers for use in ionic-electroactive or conducting polymer (CP) actuators. Its electromechanical properties surpass those of other prominent CPs such as poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT/PSS) or polyaniline. However, freestanding and linear contracting actuator fibers made solely of electropolymerized PPy are not available yet.

View Article and Find Full Text PDF

A low-cost soft sensor for sewer flow monitoring - Learning from water level measurements in manholes.

Water Res

January 2025

School of Energy and Environment, City University of Hong Kong, Hong Kong SAR, China; State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong SAR, China. Electronic address:

Flow meters are commonly used in manholes to monitor the flow rate for sewer operation and management. However, the large-scale deployment of flow meters in a sewer system is cost-prohibitive due to their high costs and the need for frequent maintenance. This paper proposes a soft sensor that estimates flow rates based on water level measurements in a manhole.

View Article and Find Full Text PDF

Flexible tactile sensors have received significant attention for use in wearable applications such as robotics, human-machine interfaces, and health monitoring. However, conventional tactile sensors face challenges in accurately measuring pressure because vertical deformation is induced by Poisson's ratio in situations where lateral strain is applied. This study shows a strain-insensitive flexible tactile sensor array without the crosstalk effect using a highly stretchable mesh.

View Article and Find Full Text PDF

Wearable Biodevices Based on Two-Dimensional Materials: From Flexible Sensors to Smart Integrated Systems.

Nanomicro Lett

January 2025

Key Laboratory of Bio-Inspired Smart Interfacial Science and Technology of Ministry of Education, School of Chemistry, Beihang University, Beijing, 100191, People's Republic of China.

The proliferation of wearable biodevices has boosted the development of soft, innovative, and multifunctional materials for human health monitoring. The integration of wearable sensors with intelligent systems is an overwhelming tendency, providing powerful tools for remote health monitoring and personal health management. Among many candidates, two-dimensional (2D) materials stand out due to several exotic mechanical, electrical, optical, and chemical properties that can be efficiently integrated into atomic-thin films.

View Article and Find Full Text PDF

The increasing demand for soft robotic systems in agricultural, biomedical and other applications has driven the development of actuators that can mimic the flexibility and adaptability of human muscles. Several studies have explored the design and implementation of soft actuators for robotic applications, however, there is a need for soft actuators demonstrating delicate gripping capabilities but also excel in specific biomedical applications, such as therapeutic massaging. The objective of this work is to develop a multi-finger soft pneumatic actuator mimicking human fingers for Ayurvedic therapeutic massaging and gripping applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!