Implant-Associated Infection of Long-Segment Spinal Instrumentation: A Retrospective Analysis of 46 Consecutive Patients.

Asian Spine J

Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.

Published: April 2021

Study Design: This single-center retrospective study analyzed patients with an implant-associated infection of spinal instrumentation (four or more segments) treated between 2010 and 2018.

Purpose: This study aimed to investigate the treatment of implant-associated infections of long-segment spinal instrumentation and to define risk factors for implant removal.

Overview Of Literature: Implant-associated infection occurs in 0.7%-20% of spinal instrumentation. Significant blood loss, delayed reoperation, and use of effective antibiotics are reported risk factors for implant removal.

Methods: Patients with superficial infections not involving the implant were excluded. All patients received surgical and antibiotic treatments according to our interdisciplinary osteomyelitis board protocol. An infection was considered healed if a patient showed no signs of infection 1 year after termination of treatment. The patients were divided into an implant retention group and implant removal group, and their clinical and microbiological data were compared.

Results: Forty-six patients (27 women, 19 men) with an implant-associated infection of long-segment spinal instrumentation and mean age of 65.3±14.3 years (range, 22-89 years) were included. The mean length of the infected instrumentation was 6.5±2.4 segments (range, 4-13 segments). Implant retention was possible in 21 patients (45.7%); in the other 25 patients (54.3%), a part of or the entire implant required removal. Late infections were associated with implant removal, which correlated with longer hospitalization. Both groups showed high postoperative complication rates (50%) and high mortality rates (8.7%). In 39 patients (84.8%), infection was eradicated at a mean follow-up of 18.9±11.1 months (range, 12-60 months). Three patients (6.5%) were lost to follow-up.

Conclusions: Implant-associated infections of long-segment spinal instrumentations are associated with high complication and mortality rates. Late infections are associated with implant removal. Treatment should be interdisciplinary including orthopedic surgeons and clinical infectiologists.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8055457PMC
http://dx.doi.org/10.31616/asj.2019.0391DOI Listing

Publication Analysis

Top Keywords

spinal instrumentation
20
implant-associated infection
16
long-segment spinal
16
implant removal
12
patients
10
implant
9
infection long-segment
8
implant-associated infections
8
infections long-segment
8
risk factors
8

Similar Publications

Intercostal neuralgia can be debilitating and extremely difficult to treat despite multi-modal therapies. The literature describing the role of neuromodulation in patients with intercostal neuralgia is scarce. In this medically challenging case report, we describe a 56-year-old male with a near complete resolution of intractable chronic intercostal neuralgia, secondary to traumatic rib fractures and multiple surgical interventions, with a single lead thoracic spinal cord stimulator (SCS) implant.

View Article and Find Full Text PDF

Introduction And Objective: Surface electromyography (sEMG) measurements are a valid method for sublesional muscle activity following spinal cord injury (SCI). In the literature there are few reports evaluating the effect of robotic assisted gait training (RAGT) on the sEMG properties change in SCI patients. The aim of this study was to evaluate the influence of RAGT on observed change of sEMG, and in 64 incomplete SCI patients in the sub-acute stage in relation to functional scales.

View Article and Find Full Text PDF

Objective: This study aims to explore the predictive value of endplate morphology and pedicle screw bone quality score on screw loosening after single-level lumbar spinal fusion surgery.

Methods: A retrospective analysis was conducted on the clinical data of 207 patients who underwent single-level lumbar spinal fusion (34 in the screw loosening group and 173 in the non-screw loosening group). Univariate analysis and binary logistic regression model analysis were performed using SPSS 27.

View Article and Find Full Text PDF

Background: Anterior cervical corpectomy and fusion (ACCF) is a standard surgical procedure for cervical spondylosis with spinal cord compression (CSWSCC), especially in patients with intensity on T2-weighted imaging high signal (T2WIHS). The titanium mesh cage (TMC) utilized in this procedure is essential in stabilizing the spine; however, the optimal slotting width of the TMC remains unclear.

Objective: This study aimed to investigate the impact of TMC slotting width on the clinical and radiological outcomes of ACCF in patients with spinal cord compression type cervical spondylosis with intensity on T2WIHS (CST2WIHS).

View Article and Find Full Text PDF

Wearable non-invasive neuroprosthesis for targeted sensory restoration in neuropathy.

Nat Commun

December 2024

Neuroengineering Laboratory, Department of Health Sciences and Technology, ETH Zurich, Zurich, Switzerland.

Peripheral neuropathy (PN), the most common complication of diabetes, leads to sensory loss and associated health issues as pain and increased fall risk. However, present treatments do not counteract sensory loss, but only partially manage its consequences. Electrical neural stimulation holds promise to restore sensations, but its efficacy and benefits in PN damaged nerves are yet unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!