Introduction: Androgenetic alopecia is the most common form of hair loss in both sexes. In recent studies, low-level light therapy (LLLT) has been established as an effective treatment for alopecia. The purpose of this study was to evaluate the safety and efficacy of LLLT using a new helmet-type device for the treatment of androgenetic alopecia.

Method: A randomized, sham device-controlled, double-blind clinical trial was conducted at 2 institutions. Sixty participants diagnosed with androgenetic alopecia aged from 19 to 65 years were recruited. LLLT was performed through a helmet-type device that emitted light with a mean output power of 2.36 mW/cm at a wavelength of 655 nm. Participants were divided into 2 groups, which respectively used the experimental device and a sham device. After tattooing at the central point of the vertex, phototrichograms at that point were obtained at 0, 8, and 16 weeks. The primary endpoint of the study was the difference in the rate of change of hair density between the test group and the control group.

Results: Comparing the results at baseline and week 16, the experimental group showed an increase in hair density of 41.90 hairs/cm and an increase in hair thickness of 7.50 μm, whereas the control group showed an increase of 0.72 hairs/cm and a decrease of 15.03 μm, respectively (P < .001). No adverse events or side effects occurred.

Conclusion: LLLT showed a significant effect on increasing hair density in patients with androgenetic alopecia. LLLT could be a safe and effective treatment for androgenetic alopecia in both sexes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7373546PMC
http://dx.doi.org/10.1097/MD.0000000000021181DOI Listing

Publication Analysis

Top Keywords

helmet-type device
12
androgenetic alopecia
12
low-level light
8
light therapy
8
device treatment
8
treatment androgenetic
8
sham device-controlled
8
hair density
8
group increase
8
increase hair
8

Similar Publications

Epidemiological analysis of the facial fractures pattern in relation to motorcycle helmet type: A retrospective study on 282 patients.

J Craniomaxillofac Surg

November 2024

Maxillofacial Surgery Unit, Department of Neurosciences, Reproductive and Odontostomatological Sciences, University Federico II, Via Pansini 5, 80100, Naples, Italy.

Article Synopsis
  • This study analyzes maxillofacial fractures from motorcycle accidents, highlighting that most injuries are caused by road traffic collisions.* -
  • It compares the impact of different helmet types (full-face, modular, and open-face) on the severity and type of facial fractures among 282 patients.* -
  • Findings reveal that full-face helmets are linked to fewer severe fractures, particularly in the midface, while open-face helmets are associated with a higher risk of mandibular and combined fractures.*
View Article and Find Full Text PDF

Background: Alopecia is one of the most common adverse effects of chemotherapy. It reduces the patient's self-esteem and quality of life and the effect of therapy. Scalp cooling is the only verified current method for prevention but success is not guaranteed, particularly after receiving anthracycline-based combinations.

View Article and Find Full Text PDF

[Multidirectional Cranial Distraction Osteogenesis for Craniosynostosis].

No Shinkei Geka

November 2022

Department of Pediatric Neurosurgery, Jichi Children's Medical Center Tochigi, Jichi Medical University.

In this article we explain in detail the Multidirectional Cranial Distraction Osteogenesis(MCDO)procedure for treating craniosynostosis, in which the multiple cranial bone flaps are pulled up in different directions by the external distractor with the helmet-type frame. MCDO has several advantages over conventional procedures such as unilateral cranial distraction osteogenesis(UCDO). First, the design of the osteotomy in MCDO is flexible depending on the deformities.

View Article and Find Full Text PDF

For PET imaging systems, a smaller detector ring enables less intrinsic spatial resolution loss due to the photon non-collinearity effect as well as better balance between production cost and sensitivity, and a hemispherical detector arrangement is more appropriate for brain imaging than a conventional cylindrical arrangement. Therefore, we have developed a brain-dedicated PET system with a hemispherical detector arrangement, which has been commercialized in Japan under the product name of VRAIN. In this study, we evaluated imaging performance of VRAIN.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!