Background: Modern consumer electronic devices and automobiles are often controlled by interfaces that sense physical gestures and spoken commands. In contrast, patient monitors and anesthesia devices are typically equipped with panel-mounted buttons, dials, and keyboards. The increased use of noncontact gesture-based interfaces in anesthesia may improve patient safety through more intuitive and prompter control of equipment and also through reduced rates of surface contamination. A novel gesture-based controller was designed and retrofitted to a standard GE Solar 8000M patient monitor. This type of technical innovation is rare, due to closely held proprietary input control systems on commercially produced clinical equipment. Nevertheless, we hypothesized that anesthesiologists would find a contactless gesture interface straightforward to use.
Methods: A gesture-based interface system was developed to control a Solar 8000M patient monitor using a millimeter-wave radar sensor. The system was programmed to detect noncontact "rotate" and "press" gestures to control the patient monitor by implementing a virtual trim knob for interface control. Fifty anesthesiologists tested a prototype interface and evaluated usability by completing a short questionnaire incorporating modified Likert scales. These evaluations were performed in a nonpatient care environment so that respondents were not adversely task loaded during assessment, also allaying any ethical or safety concerns regarding use of this novel interface for patient management.
Results: Anesthesia hardware was controlled reliably with 2 distinct gestures above the gesture sensor. The gesture-based interface generally was well received by anesthesiologists (8.09; confidence interval, 8.06-8.12 on a 10-point scale), who preferred the simpler "press" gesture to the "rotate" gesture (8.45; 8.39-8.51 vs 7.73; 7.67-7.79 on a 10-point scale; P = .005). The correlation between the preference scores for the 2 gestures from each anesthesiologist was strong (Pearson r = 0.49; 0.25-0.68; P < .001). Advancing level of training (resident, fellow, attending 1-10 years, attending >10 years) was not correlated with preference scores for either gesture (Spearman ρ = -0.02; -0.30 to 0.26; P = .87 for "press" and Spearman ρ = 0.08; -0.20 to 0.35; P = .58 for "rotate").
Conclusions: The use of gesture sensing for controlling anesthesia equipment was well received by a cohort of anesthesiologists. Even though the simpler "press" gesture was preferred over the "rotate" gesture, the intrarespondent correlation indicates that the preference for gestures as a whole is the stronger effect. No adverse relationship was found between acceptability and anesthesia experience level. Gesture sensing is a promising new area to simplify and improve the interaction between the anesthesiologist and the anesthesia workstation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7855226 | PMC |
http://dx.doi.org/10.1213/ANE.0000000000005071 | DOI Listing |
Med Phys
January 2025
OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.
Background: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Department of Neurosurgery and Department of Neuroscience, Fujian Key Laboratory of Brain Tumors Diagnosis and Precision Treatment, Xiamen Key Laboratory of Brain Center, the First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, China.
Purpose: To investigate the technique for dorsal median sulcus (DMS) mapping and assess its application value in preserving dorsal columnn (DC) function during intramedullary space occupying surgery based on a single-center experience.
Methods: A retrospective analysis was conducted on 41 cases of intramedullary spinal cord tumor admitted to the Department of Neurosurgery at the First Affiliated Hospital of Xiamen University from March 2017 to August 2023. All included cases underwent intraoperative electrophysiological monitoring, and were divided into a study group (n = 18) and a control group (n = 23), based on whether DMS mapping technique was utilized.
Int J Surg Case Rep
January 2025
Dilla University, College of Medicine and Health Sciences, Department of Obstetrics and Gynecology, Dilla, Ethiopia.
Introduction And Importance: Fibroepithelial polyps are benign growths that can occur in various anatomical locations, including the vulva. They typically present as asymptomatic skin tags that progressively increase in size.
Case Presentation: We report the case of a 30-year-old woman, para 3, who presented with a giant fibroepithelial polyp originating from the right labium majora.
J Neurosurg Case Lessons
January 2025
Department of Neurological Surgery, Pauline Braathen Neurological Center, Cleveland Clinic Florida, Weston, Florida.
Background: Radiation-induced sarcoma (RIS) is an exceptionally rare occurrence following radiation therapy, and manifestation usually occurs after a several-year latency period. Herein, the authors report the development of a radiation-induced osteosarcoma of the frontoparietal calvaria following treatment for an oligodendroglioma in an 84-year-old woman.
Observations: The patient had been diagnosed with a grade III anaplastic oligodendroglioma when she was 78 years old.
PLoS One
January 2025
Science and Technology Innovation Team of Shandong Provincial Department of Natural Resources, Shandong Institute of Land Spatial Data and Remote Sensing Technology, Jinan, China.
The increasing population density and impervious surface area have exacerbated the urban heat island effect, posing significant challenges to urban environments and sustainable development. Urban spatial morphology is crucial in mitigating the urban heat island effect. This study investigated the impact of urban spatial morphology on land surface temperature (LST) at the township scale.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!