Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCEP.120.008655 | DOI Listing |
Cardiol Res
December 2024
Department of Cardiology, Fukuoka University Hospital, Fukuoka, Japan.
An 83-year-old man underwent dual-chamber pacemaker placement for complete atrioventricular block at another hospital. The active-fixation ventricular lead was positioned on the free wall of the anterior right ventricle. Ventricular pacing failure occurred on the day after pacemaker implantation, and fluoroscopy revealed right ventricular (RV) lead perforation.
View Article and Find Full Text PDFFront Surg
April 2024
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
We report three patients with screw-in lead perforation in the right atrial free wall not long after device implantation. All the patients complained of intermittent stabbing chest pain associated with deep breathing during the implantation. The "dry" epicardial puncture was utilized to avoid hemopericardium during lead extraction in the first case.
View Article and Find Full Text PDFCureus
January 2024
Internal Medicine, Trident Medical Center, North Charleston, USA.
The implantation of an implantable cardioverter defibrillator (ICD) carries a risk for major complications, one of which is ventricular free wall rupture secondary to a lead perforation. This known complication, although rare, has estimated incidence rates between 0.1% and 3%.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
October 2024
Department of Cardiology, University Heart Center Zurich, University Hospital Zurich, Zurich, Switzerland.
Background: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population.
View Article and Find Full Text PDFCardiol Res Pract
January 2024
Daegu Catholic University Medical Center, Daegu, Republic of Korea.
Background: Boston Scientific INGEVITY+ pacing lead (Boston Scientific, Marlborough, MA, USA) has been upgraded to INGEVITY. The performance of the INGEVITY+ pacing lead has not yet been reported. This study aimed to evaluate the short- and long-term safety, effectiveness, and handling experience of INGEVITY+ leads.