A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionfrrngemn8skh6g8okthko49jliite4of): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

Active-Fixation Atrial Leads and the Risk of Atrial Fibrillation: Insights From ASSERT. | LitMetric

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.120.008655DOI Listing

Publication Analysis

Top Keywords

active-fixation atrial
4
atrial leads
4
leads risk
4
risk atrial
4
atrial fibrillation
4
fibrillation insights
4
insights assert
4
active-fixation
1
leads
1
risk
1

Similar Publications

An 83-year-old man underwent dual-chamber pacemaker placement for complete atrioventricular block at another hospital. The active-fixation ventricular lead was positioned on the free wall of the anterior right ventricle. Ventricular pacing failure occurred on the day after pacemaker implantation, and fluoroscopy revealed right ventricular (RV) lead perforation.

View Article and Find Full Text PDF

We report three patients with screw-in lead perforation in the right atrial free wall not long after device implantation. All the patients complained of intermittent stabbing chest pain associated with deep breathing during the implantation. The "dry" epicardial puncture was utilized to avoid hemopericardium during lead extraction in the first case.

View Article and Find Full Text PDF

The implantation of an implantable cardioverter defibrillator (ICD) carries a risk for major complications, one of which is ventricular free wall rupture secondary to a lead perforation. This known complication, although rare, has estimated incidence rates between 0.1% and 3%.

View Article and Find Full Text PDF

Challenges and pitfalls during CRT implantation in patients with persistent left superior vena cava.

J Interv Card Electrophysiol

October 2024

Department of Cardiology, University Heart Center Zurich, University Hospital Zurich, Zurich, Switzerland.

Background: Persistent left superior vena cava (PLSVC) is a rare venous anomaly, affecting 0.3-0.5% of the general population.

View Article and Find Full Text PDF

Background: Boston Scientific INGEVITY+ pacing lead (Boston Scientific, Marlborough, MA, USA) has been upgraded to INGEVITY. The performance of the INGEVITY+ pacing lead has not yet been reported. This study aimed to evaluate the short- and long-term safety, effectiveness, and handling experience of INGEVITY+ leads.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!