Objective: To compare clinical effects of common Kirschner wire, anatomical plate and perforated Kirschner wire in treating olecranon fracture.

Methods: From March 2014 to May 2017, clinical data of 79 patients with olecranon fracture treated with different internal fixation was retrospectively analyzed. Among them, 26 patients treated with common Kirschner wire (group A), including 19 males and 7 females aged from 23 to 51 years old with an average of (37.2±9.6) years old;11 patients were typeⅠ, and 15 patients were typeⅡ according to Mayo classification. Twenty eight patients were treated with olecroanon anatomical plate internal fixation, including 16 males and 12 females aged from 25 to 52 years old with an average of (36.6±8.9) years old;10 patientswere typeⅠ and 18 patients were typeⅡ according to Mayo classification. Twenty five patients were treated with perforated Kirschner wire, including 13 males and 12 females aged from 26 to 51 years old with an average of (38.2±9.2) years old;9 patients were typeⅠand 16 patients were typeⅡ according to Mayo classification. Operation time, intraoperatve blood loss, fracture healing time and postoperative complications among three groups were compared; VAS score at 1 week after operation was used to evaluate pain relief, Broberg-Morrey function score of elbow joint at the final follow up was applied to evaluate clinical effect.

Results: Seventy nine patients were followed up from 13 to 23 months with an average of (18.3±4.5) months. Operation time, intraoperatve blood loss, fracture healing time in group A were (82.9±19.7) min, (113.5±32.3) ml, (4.2±0.6) months respectively;in group B were(101.2±24.5) min, (150.2±39.5) ml, (4.6±0.8) months respectively;in group C were (83.3±18.7) min, (119.3±34.3) ml, (4.1±0.5) months respectively. Operation time, intraoperatve blood loss, fracture healing time in group A and group C were better than that of group B(<0.05). Five patients in group A occurred ineffective internal fixation, other groups did not occurred;9 patients in group A occurred skin irritability, 3 patients in group B and no patient occurred in group C; there were statistical differences in complications among three groups (<0.05). There were no differences in VAS score at 1 week after operation and Broberg-Morrey function score of elbow joint at the final follow-up among three groups (>0.05).

Conclusion: Common Kirschner wire has more complications; anatomical plate has greater surgical trauma and long fracture healing time;while perforated Kirschner wire was not only benefit for fracture union with less trauma, but also could reducing the incidence of postoperative complications, and it is the appropriate method for patients with olecranon fracture.

Download full-text PDF

Source
http://dx.doi.org/10.12200/j.issn.1003-0034.2020.07.003DOI Listing

Publication Analysis

Top Keywords

kirschner wire
16
internal fixation
12
patients treated
12
including males
12
males females
12
females aged
12
aged years
12
years average
12
patients typeⅡ
12
typeⅡ mayo
12

Similar Publications

Background: Kirschner wire (K-wire) and intramedullary (IM) screw fixation are accepted techniques for treatment of unstable proximal phalanx fractures, but comparative reports are lacking. This study aimed to evaluate early clinical outcomes following treatment with K-wire or IM fixation.

Methods: A retrospective review of all proximal phalanx fractures treated surgically at a single center by multiple surgeons was performed from May 1, 2019 to March 1, 2024.

View Article and Find Full Text PDF

Case: Wide resection of a synovial sarcoma of the anteromedial distal leg involving the dimetaphyseal tibia and posterior tibial tendon produced an 8.5-cm osseous defect. To keep the free flap from invaginating into the defect and prevent kinking of the anastomosis, six 1.

View Article and Find Full Text PDF

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Purpose: This study aims to compare the clinical and radiological outcomes of three different techniques used in the surgical treatment of ulnar styloid fractures.

Material And Method: Ulnar styloid fractures treated surgically between 2012 and 2022 were evaluated retrospectively. There were three groups in the study: Group I (Kirschner wire, N= 19), Group II (tension band, N= 27) and Group III (headless compression screw, N= 25).

View Article and Find Full Text PDF

Buried or exposed kirschner wires in paediatric upper extremity fracture fixation: A systematic review and meta-analysis of infection rates and complications.

Injury

January 2025

Department of Trauma and Orthopaedic Surgery, University Hospitals Plymouth NHS Trust, Derriford Hospital, Derriford Road, Plymouth, Devon, PL6 8DH, United Kingdom. Electronic address:

Background: Paediatric upper limb fractures are commonly treated with Kirschner (K) wire fixation, which can be buried or left exposed. Although both techniques are widely used, controversy remains regarding infection risk, complications, and other clinical outcomes between buried and exposed K-wires. This systematic review and meta-analysis aimed to compare infection rates and secondary outcomes between buried and exposed K-wires in paediatric upper limb fractures located distal to and including the elbow, and proximal to the carpus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!