Acetabular Revision With Intramedullary and Extramedullary Iliac Fixation for Pelvic Discontinuity.

J Arthroplasty

Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany; Regenerative Medicine, Institute of Health and Biomedical Innovation, Queensland University of Technology (QUT), Brisbane, Queensland, Australia.

Published: December 2020

Background: Parallel to the increase in revision hip procedures surgeons face more and more complex anatomical challenges with pelvic discontinuity (PD) being one of the worst-case scenarios. Here we report on our clinical results using an asymmetric acetabular component for the treatment of PD. The implant is armed in a monoblock fashion with an extramedullary iliac flange and provides the possibility to augment it with an intramedullary iliac press-fit stem.

Methods: In a single-center retrospective cohort study we analyzed prospectively collected data of 49 patients (35 female, 14 male) suffering from unilateral periprosthetic PD treated with an asymmetric acetabular component between 2009 and 2017. The mean follow-up was 71 months (21-114). Complications were documented and radiographic and functional outcomes were assessed.

Results: Kaplan-Meier analysis revealed a 5-year implant survival of 91% (confidence interval 77%-96%). The 5-year survival with revision for any cause was 87% (CI 74%-94%). The overall revision rate was 16% (n = 8). Two patients required acetabular component revision due to aseptic loosening. Four patients (8%) suffered from periprosthetic infection: one patient was treated with a 2-stage revision, and another one with resection arthroplasty. The other 2 patients were treated with debridement, irrigation, and exchange of the mobile parts. Of 6 patients (12%) suffering from hip dislocation, 2 required implantation of a dual mobility acetabular component. The mean Harris Hip Score improved from 41 preoperatively to 79 at the latest follow-up (P < .001).

Conclusion: Our findings demonstrate that an asymmetric acetabular component with extramedullary and optional intramedullary iliac fixation is a reliable and safe treatment method for periprosthetic PD resulting in good clinical and radiographic mid-term results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2020.06.067DOI Listing

Publication Analysis

Top Keywords

acetabular component
20
asymmetric acetabular
12
extramedullary iliac
8
iliac fixation
8
pelvic discontinuity
8
intramedullary iliac
8
acetabular
6
revision
5
component
5
patients
5

Similar Publications

Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.

View Article and Find Full Text PDF

Introduction: Total hip arthroplasty (THA) is recognized as one of the most effective surgical procedures for the treatment of end-stage hip arthritis. However, the increasing number of primary THA cases has led to a corresponding rise in the frequency of revision surgeries, which are often more complex and challenging due to severe acetabular bone loss. In such cases, managing Paprosky type 3A and 3B defects requires precise implant design and advanced surgical techniques.

View Article and Find Full Text PDF

Objective: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).

Materials And Methods: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained.

View Article and Find Full Text PDF

Acetabular orientation, pelvic shape, and the evolution of hominin bipedality.

J Hum Evol

January 2025

Department of Pathology and Anatomical Sciences, University of Missouri, Columbia, MO 65212, USA.

Hominin pelvic form differs dramatically from that of other primates by having more laterally facing iliac blades, a wider sacrum, and a larger, transversely broad pelvic inlet. The orientation of the acetabulum may also differ, plausibly related to differences in load transmission during upright posture and habitual bipedal locomotion, which may, in turn, affect overall pelvic geometry. We compared acetabular orientation in humans, a phylogenetically broad sample of extant anthropoid primates, and fossil hominins including Australopithecus afarensis (A.

View Article and Find Full Text PDF

Background: Total Hip Arthroplasty (THA) is a transformative surgical intervention for hip joint disorders, necessitating meticulous preoperative planning for optimal outcomes. With the emergence of Artificial Intelligence (AI), preoperative planning paradigms have evolved, leveraging AI algorithms for enhanced decision support and imaging analysis. This systematic review aims to comprehensively evaluate the role of AI in THA preoperative planning, synthesizing evidence from studies exploring various AI techniques and their applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!