The closed-head impact model of engineered rotational acceleration (CHIMERA) as an application for traumatic brain injury pre-clinical research: A status report.

Exp Neurol

Neuroscience Graduate Program, F.E. Hébert School of Medicine, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20817-4799, USA; Department of Anatomy, Physiology & Genetics, F.E. Hébert School of Medicine, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20817-4799, USA; Pre-Clinical Studies Core, Center for Neuroscience and Regenerative Medicine, F.E. Hébert School of Medicine, Uniformed Services University of the Health Sciences, 4301 Jones Bridge Road, Bethesda, MD 20817-4799, USA. Electronic address:

Published: November 2020

Closed-head traumatic brain injury (TBI) is a worldwide concern with increasing prevalence and cost to society. Rotational acceleration is a primary mechanism in TBI that results from tissue strains that give rise to diffuse axonal injury. The Closed-Head Impact Model of Engineered Rotational Acceleration (CHIMERA) was recently introduced as a method for the study of impact acceleration effects in pre-clinical TBI research. This review provides a survey of the published literature implementing the CHIMERA device and describes pathological, imaging, neurophysiological, and behavioral findings. Findings show CHIMERA inflicts damage in white matter tracts as a key area of injury. Behaviorally, repeated studies have shown motor deficits and more chronic cognitive effects after CHIMERA injury. Good progress with model application has been accomplished by investigators attending to what is required for model validation. However, the majority of CHIMERA studies only utilize adult male mice. To further establish this model, more work with female animals and various age groups need to be performed, as well as studies to further establish and standardize methodologies for validation of the models for clinical relevance. Common data elements to standardize the reporting methodology for the CHIMERA literature are suggested.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.expneurol.2020.113409DOI Listing

Publication Analysis

Top Keywords

rotational acceleration
12
closed-head impact
8
impact model
8
model engineered
8
engineered rotational
8
acceleration chimera
8
traumatic brain
8
brain injury
8
chimera
7
model
5

Similar Publications

Shoulder and elbow injuries are prevalent among baseball players, particularly pitchers, who experience repetitive eccentric loading of the shoulder, leading to muscle damage and increased injury risk. Nearly 40% of shoulder injuries in baseball occur in pitchers, with many facing low rates of return to sport. The rotator cuff (RC) muscles-supraspinatus (SSP), infraspinatus (ISP), subscapularis (SSC), and teres minor (TMin)-are crucial for shoulder stability, movement, and force generation, particularly in overhead sports.

View Article and Find Full Text PDF

Analysis and Testing of a Flyable Micro Flapping-Wing Rotor with a Highly Efficient Elastic Mechanism.

Biomimetics (Basel)

December 2024

Centre for Aeronautics, Faculty of Engineering and Applied Sciences, Cranfield University, Bedford MK43 0AL, UK.

A Flapping-Wing Rotor (FWR) is a novel bio-inspired micro aerial vehicle configuration, featuring unique wing motions which combine active flapping and passive rotation for high lift production. Power efficiency in flight has recently emerged as a critical factor in FWR development. The current study investigates an elastic flapping mechanism to improve FWRs' power efficiency by incorporating springs into the system.

View Article and Find Full Text PDF

Purpose: To evaluate the healing of meniscal repair performed concomitantly with anterior cruciate ligament reconstruction (ACLR) using second-look arthroscopy, and the relationship between meniscal healing and knee laxity using quantitative evaluation under anesthesia.

Methods: This retrospective study included patients who underwent primary double-bundle ACLR with meniscal repair between June 2016 and June 2021, with a two-year minimum follow-up. Meniscal healing was evaluated by second-look arthroscopy at least one year postoperatively, and knee laxity was measured under general anesthesia preoperatively, intraoperatively, and at second-look.

View Article and Find Full Text PDF

This study investigates human semicircular canal (SCC) dynamics under off-center rotational conditions. Previous research has modeled human rotational perception and the dynamic response of the SCCs by assuming a centered rotation state, where the rotation axis aligns with the SCC's center. However, this assumption is not representative of most real-life rotational situations.

View Article and Find Full Text PDF

For over a century, the Hall effect, a transverse effect under an out-of-plane magnetic field or magnetization, has been a cornerstone for magnetotransport studies and applications. Modern theoretical formulation based on the Berry curvature has revealed the potential that even an in-plane magnetic field can induce an anomalous Hall effect, but its experimental demonstration has remained difficult due to its potentially small magnitude and strict symmetry requirements. Here, we report observation of the in-plane anomalous Hall effect by measuring low-carrier density films of magnetic Weyl semimetal EuCd_{2}Sb_{2}.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!