Picoliter enzyme reactor on a nanofluidic device exceeding the bulk reaction rate.

Analyst

Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan.

Published: August 2020

Single-cell analyses have recently become important to understand cell heterogeneity, the mechanism of cell function, and diseases. In contrast to single-cell analyses that target nucleic acids, single-cell protein analyses still pose challenges. We have proposed a general concept of integration and extended this concept to the 10-1000 nm scale with femtoliter-picoliter volumes which are smaller than the volume of a single cell exploring ultimate analytical performances (e.g. single-cell target proteomics). However, single-cell shotgun proteomics, which is used to analyze even unknown proteins, is still challenging because there is no digestion column with picoliter volume. The issues were long reaction time (overnight) and much larger reaction volume (microliter) in the conventional bulk method. In this study, an ultra-fast picoliter enzyme reactor using a nanochannel was developed. A device with a channel depth of 300 nm and a volume of 32.4 pL was fabricated. To prevent the self-digestion of trypsin (enzyme), the picoliter enzyme reactor was prepared by immobilizing trypsinogen which was activated to trypsin by enterokinase. The enzyme density obtained by the trypsinogen immobilization process was 2.5 times higher than that obtained by the conventional trypsin immobilization process. Furthermore, the apparent enzyme concentration was 36 times higher due to an extremely high surface-to-volume ratio of the nanochannel, compared to the limit concentration in the bulk. Finally, the enzyme reaction in the picoliter enzyme reactor was accelerated 25 times compared to that in the bulk. Using the picoliter enzyme reactor, protein solution with picoliter volume will be digested without self-digestion and artificial modification, which will greatly contribute to single-cell shotgun proteomics.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d0an00998aDOI Listing

Publication Analysis

Top Keywords

picoliter enzyme
20
enzyme reactor
20
single-cell analyses
8
single-cell shotgun
8
shotgun proteomics
8
picoliter volume
8
enzyme
8
immobilization process
8
times higher
8
picoliter
7

Similar Publications

Machine Learning-Assisted, Dual-Channel CRISPR/Cas12a Biosensor-In-Microdroplet for Amplification-Free Nucleic Acid Detection for Food Authenticity Testing.

ACS Nano

December 2024

State Key Laboratory of Food Nutrition and Safety, Key Laboratory of Industrial Microbiology, Ministry of Education, Tianjin Key Laboratory of Industry Microbiology, National and Local United Engineering Lab of Metabolic Control Fermentation Technology, China International Science and Technology Cooperation Base of Food Nutrition/Safety and Medicinal Chemistry, College of Biotechnology, Tianjin University of Science & Technology, Tianjin 300457, China.

The development of novel detection technology for meat species authenticity is imperative. Here, we developed a machine learning-supported, dual-channel biosensor-in-microdroplet platform for meat species authenticity detection named CC-drop (RISPR/Cas12a digital single-molecule microdroplet biosensor). This strategy allowed us to quickly identify and analyze animal-derived components in foods.

View Article and Find Full Text PDF

Analysis of single cancer cells is critical to obtain accurate patient diagnosis and prognosis. In this work, we report the selective dielectrophoretic capture and electrochemical analysis of single melanoma cells at an array of interlocked spiral bipolar electrodes (iBPEs). Following dielectrophoretic capture, individual melanoma cells are hydrodynamically transferred into picoliter-scale chambers for subsequent analysis.

View Article and Find Full Text PDF

Protein design and directed evolution have separately contributed enormously to protein engineering. Without being mutually exclusive, the former relies on computation from first principles, while the latter is a combinatorial approach based on chance. Advances in ultrahigh throughput (uHT) screening, next generation sequencing and machine learning may create alternative routes to engineered proteins, where functional information linked to specific sequences is interpreted and extrapolated .

View Article and Find Full Text PDF

Droplet-based microfluidics and enzyme evolution.

Curr Opin Biotechnol

June 2024

Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Vladimir Prelog Weg 1, 8093 Zürich, Switzerland. Electronic address:

Enzymes are widely used as catalysts in the chemical and pharmaceutical industries. While successful in many situations, they must usually be adapted to operate efficiently under nonnatural conditions. Enzyme engineering allows the creation of novel enzymes that are stable at elevated temperatures or have higher activities and selectivities.

View Article and Find Full Text PDF

Digital metabolic activity assay enables fast assessment of 2D materials bactericidal efficiency.

Anal Chim Acta

January 2024

School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore, 639798, Singapore. Electronic address:

Background: The identification and quantification of viable Escherichia coli (E. coli) are important in multiple fields including the development of antimicrobial materials, water quality, food safety and infections diagnosis. However, the standard culture-based methods of viable E.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!