Background: Oral appliance (OA) treatment for obstructive sleep apnea syndrome (OSAS) has attracted more and more attention due to its low price, comfort, portable and non-invasion. This study aimed to investigate the clinical effectiveness of adjustable oral appliance on older adult patients with OSAS.

Methods: Thirty older adult patients diagnosed with OSAS were chosen as the study participants and received an adjustable OA for 6 months. Then, the patients were subjected to a polysomnographic examination, Berlin Questionnaire (BQ) scale questionnaire, and cone beam computer tomography (CBCT) analytical measurement to evaluate their symptom improvement and the morphologic changes of the upper airway.

Results: After treatment with adjustable oral appliance for six months, the results showed that there was an improvement of different degrees in the subjective symptoms. Apnea hypopnea index (AHI) had decreased from (27.65±1.31) per hour to (6.74±0.75) per hour (P<0.05); the maximum apnea time (MAT) had decreased from 43.82±2.69 to 21.37±3.18 s (P<0.05); the average oxygen saturation (MSaO2) had increased from (89.24±7.27)% to (92.69±4.46)%; the lowest oxygen saturation (LSaO2) from (81.85±8.31)% to (86.93±4.45)%. Moreover, the CBCT scanning analysis showed that the minimal sagittal diameter, sectional area, and the volume of the palatopharynx, as well as the sagittal diameter and volume of the glossopharynx significantly increased.

Conclusions: The adjustable OA had considerable clinical efficacy and comfort in older adult OSAS patients by enlarging the palatopharynx and glossopharynx.

Download full-text PDF

Source
http://dx.doi.org/10.21037/apm-20-1300DOI Listing

Publication Analysis

Top Keywords

oral appliance
16
adjustable oral
12
older adult
12
adult patients
12
effectiveness adjustable
8
appliance older
8
obstructive sleep
8
sleep apnea
8
apnea syndrome
8
oral
4

Similar Publications

Introduction: Obstructive sleep apnoea (OSA) is characterised by blood oxygen desaturations and sleep disruptions manifesting undesirable consequences. Existing treatments including oral appliances, positive airway pressure (PAP) therapy and surgically altering the anatomy of the pharynx have drawbacks including poor long-term adherence or often involving irreversible, invasive procedures. Bilateral hypoglossal nerve stimulation (HNS) is a new treatment for managing OSA, and this study is intended to determine whether an HNS system is a safe and effective treatment option for adults with OSA.

View Article and Find Full Text PDF

The effect of mandibular advancement on pharyngeal airway space in patients with oral squamous cell carcinoma: A monocentric prospective study with computed tomography.

Clin Oral Investig

January 2025

Department of Oral and Maxillofacial Surgery, Klinikum Rechts Der Isar, School of Medicine and Health, Technische Universität München, Ismaninger Str. 22, Munich, D-81679, Germany.

Objectives: The presented study aimed to evaluate the effect of mandibular protrusion with a temporarily applied mandibular advancement device (MAD) on the posterior airway space and to determine a reliable metric constant based on a three-dimensional computed tomography (CT) evaluation.

Materials And Methods: The study population consisted of patients with oral squamous cell carcinoma who were treated at least six months prior to the follow-up CT in supine position. Each patient received an individually adjusted MAD that was temporarily applied with three different protrusion distances (P = 0 mm, P = 4 mm, and P = 8 mm) during follow-up CT.

View Article and Find Full Text PDF

Twin block appliances are commonly used to treat skeletal class II malocclusion. However, many adverse effects, such as lower incisor protrusion and a bulky nature, can be observed. To overcome these effects, a modified twin block was designed, which uses vacuum-formed hard plates (VFPs) instead of acrylic plates.

View Article and Find Full Text PDF

Background And Purpose:  Early migration of the uncemented cruciate-sacrificing rotating platform ATTUNE and Low Contact Stress (LCS) tibial components was classified as at-risk for aseptic loosening rates exceeding 6.5% at 15 years based on recent fixation-specific migration thresholds. In this secondary report of a randomized controlled trial (RCT) we aimed to evaluate whether the 5-year migration, inducible displacement, and the clinical outcome of the ATTUNE components were comparable to those of the LCS.

View Article and Find Full Text PDF

Chessboard-like Burn Wound Healing Model of Mice Based on Digital Heating Device.

J Vis Exp

December 2024

State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University; Department of Endodontics, West China Hospital of Stomatology, Sichuan University;

Severe burn injuries are among the most traumatic and physically debilitating conditions, impacting nearly every organ system and resulting in considerable morbidity and mortality. Given their complexity and the involvement of multiple organs, various animal models have been created to replicate different facets of burn injury. Methods used to produce burned surfaces vary among experimental animal models.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!