Introduction: We sought to identify the incidence of new 90-day cardiac events, 90-day mortality, 90-day unplanned readmissions, and 30-day emergency department (ED) visits after total joint arthroplasty (TJA) in patients with a history of a cardiac implantable electronic device (CIED) and compare these outcomes in TJA patients without a CIED.
Methods: Kaiser Permanente's Cardiac Device and Total Joint Replacement Registries were used to identify elective primary TJA performed for osteoarthritis. TJA with a CIED was matched with TJA without a CIED (n = 365 pairs) on patient characteristics, demographics, and procedure type. A McNemar test was used to evaluate categorical outcomes.
Results: Of the TJA with a CIED, there were 24 cardiac events (6.6%), 1 mortality (0.3%), 30 readmissions (8.2%), and 39 ED visits (10.7%). TJA patients with a CIED had a higher likelihood of cardiac events (odds ratio [OR] = 3.14, 95% confidence interval [CI] = 1.28 to 8.08). No difference was observed in mortality (OR = 0.50, 95% CI = 0.02 to 6.98), readmissions (OR = 1.26, 95% CI = 0.71 to 2.25), or ED visits (OR = 1.15, 95% CI = 0.71 to 1.88).
Conclusion: In our matched cohort study, TJA patients with a history of a CIED had a higher likelihood of incident 90-day cardiac events when compared with patients without a CIED without a difference observed for 90-day mortality, unplanned readmission, and 30-day ED visit.
Level Of Evidence: Level III.