[The Monitoring and Application of Transcranial Doppler Ultrasound in Patients with Severe Neurovascular Diseases].

Sichuan Da Xue Xue Bao Yi Xue Ban

Department of Neurological Intensive Critical Care, West China Hospital, Sichuan University, Chengdu 610041, China.

Published: July 2020

Objective: To investigate the monitoring effect and application of transcranial Doppler ultrasound (TCD) in patients with severe neurovascular cerebrovascular diseases.

Methods: From December 2016 to October 2018, 96 patients with cerebrovascular disease in Department of Neurology and ICU, West China Hospital, Sichuan University were monitored by bedside TCD, including the detection of bilateral middle cerebral arteries (MCAs) through temporal window, and the detection of the basilar artery (BA) through occipital window, characterized by the peak systolic blood flow velocity, peak diastolic blood flow velocity, average peak blood flow velocity, vascular pulsatility index, vascular pulsatility index, vascular resistance index and blood flow spectrum morphology in local hemodynamic changes. According to the monitoring results, it was divided into vasospasm group, increased blood flow group and insufficient blood supply group. Relevant data of monitoring results were analysed.

Results: Bedside TCD monitoring was successfully used to all cerebrovascular diseases patients. Among 96 patients, 37 patients (38.54%) had increased cerebral blood flow, 15 patients (15.62%) had cerebral vasospasm, and 93 patients had insufficient cerebral blood supply (90.62%, including insufficient blood supply to the MCA and BA). Patients mainly with cerebral aneurysm and hypertensive intracerebral hemorrhage types contributed the highest proportion of insufficient blood supply, followed by the increase of blood flow, and the incidence of vasospasm was relatively low. In cerebral aneurysm group and hypertensive intracerebral hemorrhage group, and differences in the incidence of insufficient blood supply, increased blood flow, and vasospasm were statistically significant ( <0.05).

Conclusion: The bedside TCD monitoring can assess the patient's craniocerebral hemodynamic information and provide a clinical guidance.

Download full-text PDF

Source
http://dx.doi.org/10.12182/20200760606DOI Listing

Publication Analysis

Top Keywords

blood flow
32
blood supply
20
insufficient blood
16
blood
13
flow velocity
12
patients
9
monitoring application
8
application transcranial
8
transcranial doppler
8
doppler ultrasound
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!