Cor triatriatum is a rare congenital cardiac anomaly. Majority of the cases present in the childhood with an incidence of 0.4%. However, we report a case of cor triatrium sinister with ostium secundum atrial septal defect (ASD) in a 39-year-old female. The intraoperative 3D transesophageal echocardiography (TEE) offers an advantage over 2D TEE in visualizing the interatrial septum and the attachments of the fibromuscular accessory membrane in the left atrium (LA), which could help in surgical decision-making in this patient.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7559954PMC
http://dx.doi.org/10.4103/aca.ACA_131_19DOI Listing

Publication Analysis

Top Keywords

intraoperative transesophageal
8
cor triatriatum
8
ostium secundum
8
secundum atrial
8
atrial septal
8
septal defect
8
transesophageal echocardiographic
4
echocardiographic assessment
4
assessment cor
4
triatriatum ostium
4

Similar Publications

Carbon dioxide gas emboli is a potentially fatal complication that occurs more frequently during laparoscopic hepatectomy compared to other laparoscopic surgeries. The patient featured in this report had massive gas embolism confirmed by intraoperative transesophageal echocardiography (TEE) that were associated with episodes of severe hypoxemia, hemodynamic instability, and right ventricular failure requiring conversion to open hepatectomy. Abrupt abdominal decompression resulted in massive hemorrhage from a previously undetected defect in the middle hepatic vein.

View Article and Find Full Text PDF

Subvalvular aortic stenosis typically manifests at a young age and rarely presents in adulthood. It may cause left ventricular outflow tract stenosis, which requires surgical treatment in severe cases. The coexistence of discrete subvalvular aortic stenosis and quadricuspid aortic valve is a highly unusual finding.

View Article and Find Full Text PDF

We describe a rare but interesting complication of totally endoscopic robotic mitral valve repair in a patient with severe mitral regurgitation. The mitral valve was repaired robotically by standard techniques, and the intraoperative transesophageal echocardiogram demonstrated no residual mitral regurgitation. However, there was unexpected hypokinesia of the posterior and lateral walls of the left ventricle, with subsequent electrocardiography showing acute ST elevations of the lateral segment.

View Article and Find Full Text PDF

The surgical procedure detailed in this case report focuses on the treatment of a large cardiac hydatid cyst located in the intraventricular septum. The surgical intervention comprised a comprehensive approach involving a median sternotomy and cardiopulmonary bypass. A localized mass below the tricuspid valve at the basal region of the interventricular septum was revealed.

View Article and Find Full Text PDF

In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO versus a direct CO blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity.

View Article and Find Full Text PDF