Arm position on portable neonatal/infant ICU chest radiograph can mimic lamellar effusion.

J Med Imaging Radiat Sci

Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA; Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA. Electronic address:

Published: December 2020

Introduction/background: Arm malposition in neonatal ICU radiographs may result in overlap of the arm soft tissues and chest wall giving the appearance of lamellar effusions. We aimed to determine the frequency of arm malposition on portable neonatal/infant intensive care unit (N/IICU) chest radiographs and the proportion of these mimicking lamellar effusions.

Material And Methods: We evaluated a subgroup of supine portable chest radiographs performed at the N/IICU. Two reviewers, at a tertiary pediatric hospital located in the USA, evaluated each radiograph in consensus and classified arm position for either side independently as (1) acceptable: arm abducted and separated from the chest and (2) compromised: arm down and in contact with chest soft tissue. The compromised cases were evaluated regarding any overlap between soft tissues of the arm and chest of sufficient degree to mimic a lamellar effusion.

Results: We reviewed 300 radiographs performed at the N/IICU (600 hemithoraces). The mean age was 1.8 ± 1.8 months. Of 600 hemithoraces, 233 (39%) showed arms down and in contact with the chest. In seven (1%) cases, the arm position was compromised and mimicked a lamellar effusion. We identified 32 (5%) true lamellar effusions in the whole sample; in 14 of the 32 cases with lamellar effusion, the radiographs were performed with the arms down.

Conclusion: Portable chest radiographs performed in the N/IICU without proper arm abduction represent a potential for misinterpretation of chest radiographs. Although the prevalence of mimickers of lamellar effusion is only around 1%, the prevalence of arms down on a portable chest radiograph is considerably high (39%).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmir.2020.07.001DOI Listing

Publication Analysis

Top Keywords

lamellar effusion
16
chest radiographs
16
radiographs performed
16
arm position
12
portable chest
12
performed n/iicu
12
chest
11
arm
10
portable neonatal/infant
8
chest radiograph
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!