Purpose: The purpose of this study was to define dose constraints for catheter insertion sites to minimize probability of prominent post-therapy skin marks after interstitial breast brachytherapy.
Methods And Materials: Forty patients who had undergone interstitial breast brachytherapy were studied at followup at least 2 years after the procedure. Their implant marks were compared with background skin and areola and scored as Gr0 = invisible (same color as surrounding skin), Gr1 = darker than surrounding skin but lighter than areola or hypopigmentation, and Gr2 = same color as areola or darker. Highest point doses received in each plane of implant and their corresponding closest distances from clinical target volume, 85% isodose, and closest catheter dwell point were used for analysis. A logistic regression was performed to ascertain effects of various dosimetric parameters on the probability of Gr2 marks. Receiver operating characteristic curve was generated to derive cutoffs.
Results: A total of 280 dose points were studied. Median values for various parameters were 1.4 Gy (0.24-3.74) for Dose max and 1.6 cm, 1.5 cm, and 1.0 cm for Dist CTV min, Dist Iso min, and Dist Dwell min, respectively. On logistic regression, increasing Dose max alone was associated with an increased likelihood of developing Gr2 marks. Each unit increase of Dose max increased probability of development of Gr2 skin marks by 5.0% (2.391-10.328). Receiver operating characteristic analysis also showed greatest odd ratio (8.0), sensitivity (74.8%), and specificity (73%) for Dose max.
Conclusions: It seems prudent to restrict dose to catheter insertion sites for better cosmesis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.brachy.2020.06.008 | DOI Listing |
Heart Fail Rev
January 2025
Division of Cardiovascular Medicine, University of Utah Health & School of Medicine, 30 N Mario Capecchi Drive, HELIX Building 3rd Floor, Salt Lake City, UT, 84112, USA.
Right heart catheterization (RHC) provides critical hemodynamic insights by measuring atrial, ventricular, and pulmonary artery pressures, as well as cardiac output (CO). Although the use of RHC has decreased, its application has been linked to improved outcomes. Advanced hemodynamic markers such as cardiac power output (CPO), aortic pulsatility index (API), pulmonary artery pulsatility index (PAPi), right atrial pressure to pulmonary capillary wedge pressure ratio (RAP/PCWP) and right ventricular stroke work index (RVSWI) have been introduced to enhance risk stratification in cardiogenic shock (CS) and end-stage heart failure (HF) patients.
View Article and Find Full Text PDFPediatr Cardiol
January 2025
The Heart Center, Nationwide Children's Hospital, Columbus, OH, USA.
The C3PO collaborative, with a history of successful quality improvement (QI) initiatives, leveraged registry participants to develop a multi-center QI initiative to reduce adverse events (AEs) in congenital cardiac catheterization. A 32-person, interdisciplinary working group analyzed audited data for all congenital cardiac catheterization cases from 2014-2017. The primary outcome was the occurrence of any high-severity (level 3/4/5) AE.
View Article and Find Full Text PDFImportance: Postoperative urinary retention (POUR) is common after reconstructive pelvic surgery. Little is known about the relationship between older age (≥70 years) and POUR after pelvic organ prolapse surgery.
Objectives: We aimed to investigate the relationship between age ≥70 years and POUR.
J Soc Cardiovasc Angiogr Interv
December 2024
Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center of Utrecht, Utrecht, the Netherlands.
Background: Three-dimensional rotational angiography (3DRA) is a promising advancement to guide cardiac catheterizations. It is used with restraint in critically ill infants with congenital heart disease (CHD) due to the lack of research conducted within this patient group.
Methods: Data of all infants with CHD and a body weight <5 kg who underwent cardiac catheterization with the use of 3DRA between November 2011 and April 2021 were retrospectively analyzed.
J Soc Cardiovasc Angiogr Interv
December 2024
Cardiovascular Institute, Detroit Medical Center, DMC Heart Hospital, Detroit, Michigan.
Transcatheter aortic valve repair (TAVR) presents a minimally invasive alternative to traditional surgical valve replacement, albeit not without its own set of complications. A rare complication is the infolding of the self-expanding valve, which can precipitate cardiac arrest. The estimated incidence rate of this complication stands at 1.