Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7332902PMC
http://dx.doi.org/10.1016/j.mehy.2020.110071DOI Listing

Publication Analysis

Top Keywords

transpulmonary electrotherapy
4
electrotherapy reduction
4
reduction lung
4
lung viral
4
viral load
4
load sars-cov-2
4
sars-cov-2 patients
4
patients covid-19
4
transpulmonary
1
reduction
1

Similar Publications

This series describes an innovative technique for pacing in patients with sinus node dysfunction after extracardiac Fontan surgery. This transpulmonary approach to the left atrial epi-myocardium has been successfully applied to three patients at two centers and resulted in excellent acute and midterm pacing characteristics without known complications. The principal advantage of this procedure in comparison to prior iterations is the absence of pacing material within the pulmonary venous atrium, so that future systemic thromboembolism risk is minimized.

View Article and Find Full Text PDF

Mechanical ventilation (MV) is associated with hippocampal apoptosis and inflammation, and it is important to study strategies to mitigate them. To explore whether temporary transvenous diaphragm neurostimulation (TTDN) in association with MV mitigates hippocampal apoptosis and inflammation after 50 hours of MV. Normal-lung porcine study comparing apoptotic index, inflammatory markers, and neurological-damage serum markers between never-ventilated subjects, subjects undergoing 50 hours of MV plus either TTDN every other breath or every breath, and subjects undergoing 50 hours of MV (MV group).

View Article and Find Full Text PDF

Objectives: Haemodynamic monitoring during post arrest care is important to optimise treatment. We compared stroke volume measured by minimally-invasive monitoring devices with or without thermodilution calibration, and transthoracic echocardiography (TTE), and hypothesised that thermodilution calibration would give stroke volume index (SVI) more in agreement with TTE during targeted temperature management (TTM).

Design: Comatose out-of-hospital cardiac arrest survivors receiving TTM (33 °C for 24 hrs) underwent haemodynamic monitoring with arterial pulse contour analyses with (PiCCO2®) and without (FloTrac/Vigileo monitor) transpulmonary thermodilution calibration.

View Article and Find Full Text PDF

Objectives: Patients with decreased left ventricular function undergoing cardiac surgery have a greater chance of difficult weaning from cardiopulmonary bypass and a poorer clinical outcome. Directly after weaning, interventricular dyssynchrony, paradoxical septal motion, and even temporary bundle-branch block might be observed. In this study, the authors measured arterial dP/dt, mean arterial pressure (MAP), and cardiac index using transpulmonary thermodilution, pulse contour analysis, and femoral artery catheter and compared the effects between right ventricular (A-RV) and biventricular (A-BiV) pacing on these parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!