  • Intraoperative fluoroscopy enhances total hip arthroplasty accuracy but may cause image distortion, prompting a study comparing the manual gridding system (MGS) and digital gridding system (DGS) for component placement.
  • MGS showed higher success rates in achieving targeted acetabular cup abduction (ABD) and lower average ABD angles compared to DGS, though both methods had similar outcomes for leg length discrepancy (LLD) and global hip offset (GHO).
  • Overall, both MGS and DGS effectively placed components within target zones, with MGS being slightly more consistent, but these differences are not likely to impact clinical results significantly.

Article Abstract

Background: Intraoperative fluoroscopy is beneficial when performing total hip arthroplasty (THA) via the direct anterior approach; however, image distortion may influence component placement. A manual gridding system (MGS) and a digital gridding system (DGS) are commercially available, aimed at visually representing or correcting image distortion. Therefore, the purpose of this study is to compare component placement accuracy following direct anterior approach THA when intraoperative fluoroscopy was supplemented with MGS or DGS.

Methods: A retrospective evaluation of acetabular cup abduction (ABD), leg length discrepancy (LLD) and global hip offset difference (GHO) was completed for consecutive patients from 6 week post-THA weight-bearing radiographs. The predefined target LLD and GHO was <10 mm and ABD target was 45° ± 10°. Differences between MGS and DGS were determined by independent t-tests.

Results: The MGS (250 patients, 315 hips) and DGS (183 patients, 218 hips) achieved targeted ABD in 98.7% and 96.8% of cases, respectively, and ABD was significantly lower in the MGS group (45.14 ± 4.03° and 47.01 ± 4.39°, respectively) (P < .001). Compared to MGS, the DGS group averaged significantly higher GHO (3.64 ± 2.44 and 4.45 ± 2.73 mm, respectively, P = .002) but was not significantly different regarding LLD (2.92 ± 2.55 and 3.19 ± 2.46 mm, respectively, P = .275). No significant group difference was noted for percentage within the targeted LLD and GHO; however, 93.5% of DGS and 97.6% of MGS achieved all three (P = .031).

Conclusion: The use of both the MGS and DGS resulted in consistent component placement within the predefined target zone. Although the MGS appeared to be slightly more consistent, these differences are unlikely to be clinically significant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2020.06.053DOI Listing

Publication Analysis

Top Keywords

component placement
12
direct anterior
12
placement accuracy
8
total hip
8
hip arthroplasty
8
intraoperative fluoroscopy
8
anterior approach
8
image distortion
8
gridding system
8
comparison component
4

Similar Publications

Anthropogenic emissions of non-CO greenhouse gases, such as low-concentration coal mine methane (cCH < 30 vol%), have a significant impact on global warming. The main component of coal mine methane is methane (CH), which is both a greenhouse gas and a high-quality clean energy gas. To study the combustion and heat transfer reactions of low-concentration coal mine methane in a catalytic oxidation device, a numerical simulation approach was employed to establish a model of the catalytic oxidation device that includes periodic boundary conditions, methane combustion mechanisms, and turbulent-laminar flow characteristics.

View Article and Find Full Text PDF

Hip arthroplasty in patients with a history of paediatric hip disorders presents a significant challenge for orthopaedic surgeons. These patients are typically younger and have greater functional demands. Therefore, achieving optimal biomechanical conditions is crucial, involving placement of the acetabulum at the ideal centre of rotation and securing a stable femoral component with good offset to preserve abductor muscle function and restore leg length.

View Article and Find Full Text PDF

Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.

Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.

View Article and Find Full Text PDF

Autism spectrum disorder (ASD) is a prevalent neurodevelopmental disorder characterized by social, communication, and behavioral challenges. Emergency medical services (EMS) environments, with their loud noises, bright lights, and unfamiliar personnel, often exacerbate these challenges, making care for individuals with ASD particularly complex. To address these challenges, the Franciscan Crown Point EMS system introduced the "Ben's Blue Bags" (BBBs) program.

View Article and Find Full Text PDF

The surgical repair of giant inguinal hernias with loss of domain, defined as the relocation of the majority of the intestine into the hernia sac, poses a significant challenge. In the majority of cases, a combination of different surgical techniques with the placement of multiple meshes is necessary to achieve reduction of such complex hernias. The reduction of chronic giant hernias can increase the risk of abdominal compartment syndrome or cardiopulmonary complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!