Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Injury of the renal collecting system is a well-known complication of percutaneous nephrolithotomy (PNL). Large injuries may cause excessive bleeding and fluid extravasation and require adequate drainage using several modalities such placement of JJ stents. Herein, we report on two cases in which the upper coil of the JJ stent got buried in the fibrous tissues which formed due to an injury of the collecting system during PNL.
Case Presentation: 40 years old male and 32 years old female underwent standard PNL for partial and total staghorn calculi, respectively. During the procedure in both cases, the renal pelvis was injured. In both cases, JJ stent was used to drain the collecting system. Trial to remove the JJ stent 6 weeks following the procedure failed because the upper coils of the stents were embedded in the fibrous tissues at the perforation site. Laser incision of the fibrous tissues and releasing the upper coil of the stents were performed using percutaneous approach in the first case and flexible ureterorenoscopy (fURS) in the second patient. The procedures were uneventful in both cases.
Conclusion: This is the first report of embedded JJ stents which got buried by fibrous tissues at the site of collecting system injury that occurred during PNL. To prevent this complication in such cases, we suggest draining the collecting system using nephrostomy tube instead of JJ stent. Alternatively, the upper coil of the stent should be placed away from the injury site.