We report the experimental observation of more than four Fermi-Pasta-Ulam-Tsingou recurrences in an optical fiber thanks to an ultra-low loss optical fiber and to an active loss compensation system. We observe both regular (in-phase) and symmetry-broken (phase-shifted) recurrences, triggered by the input phase. Experimental results are confirmed by numerical simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.391560DOI Listing

Publication Analysis

Top Keywords

optical fiber
12
observation fermi-pasta-ulam-tsingou
8
fermi-pasta-ulam-tsingou recurrences
8
recurrences ultra-low-loss
4
ultra-low-loss optical
4
fiber report
4
report experimental
4
experimental observation
4
recurrences optical
4
fiber ultra-low
4

Similar Publications

Characterization and risk assessment of microplastics in shoreline sediments of the Yellow River Delta.

Mar Environ Res

December 2024

Institute of Ocean Research, Peking University, Beijing 100871, China; College of Urban and Environmental Sciences, Peking University, Beijing 100871, China. Electronic address:

As the intersection of river, sea, and land, river deltas are hotspots for the accumulation of microplastics (MPs). This study investigated the abundance and characteristics of MPs in surface sediments from shoreline area of the Yellow River Delta in northern China, elucidated their sources, and assessed their risk. The MPs isolated from sediment samples were detected and characterized using optical microscopy and micro-Fourier transform infrared spectroscopy (μ-FTIR).

View Article and Find Full Text PDF

This study offers a comprehensive analysis of the Perturbed Schrödinger -Hirota Equation (PSHE), crucial for understanding soliton dynamics in modern optical communication systems. We extended the traditional Nonlinear Schrödinger Equation (NLSE) to include higher-order nonlinearities and spatiotemporal dispersion, capturing the complexities of light pulse propagation. Employing the modified auxiliary equation method and Adomian Decomposition Method (ADM), we derived a spectrum of exact traveling wave solutions, encompassing exponential, rational, trigonometric, and hyperbolic functions.

View Article and Find Full Text PDF

This study assessed the impact of race and ethnicity on longitudinal test variability and time to detect glaucoma progression using standard automated perimetry (SAP) and optical coherence tomography (OCT). The sample consisted of 47,003 SAP tests from 5402 eyes and 25,480 OCT tests from 4125 eyes, with 20% of participants self-identifying as Black or African American and 80% as White; 29% as Hispanic or Latino and 71% as Not Hispanic or Latino. Variability was measured using standard deviations of residuals from linear regression models for SAP mean deviation (MD) and OCT retinal nerve fiber layer (RNFL) thickness over time.

View Article and Find Full Text PDF

Purpose: To compare the retinal nerve fiber layer (RNFL), ganglion cell-inner plexiform layer thickness, central subfield thickness (CSFT), and parafoveal and perifoveal thickness in children of different age groups with young adult controls by using spectral-domain optical coherence tomography.

Methods: This cross-sectional study included children aged 6-17 years and adult controls (18-22 years) - group 1: 6-9 years (57 eyes), group 2: 10-13 years (116 eyes), group 3: 14-17 years (66 eyes), and group 4 (controls): 18-22 years (61 eyes). A mixed-effects model was used to compare the OCT parameters among the groups, along with multivariable analysis.

View Article and Find Full Text PDF

A Highly Stable Electrochemical Sensor Based on a Metal-Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat.

Biosensors (Basel)

December 2024

Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.

The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!