Fabricating a Raman spectrometer using an optical pickup unit and pulsed power.

Sci Rep

Department of Chemistry Education, Graduate Department of Chemical Materials, Institute for Plastic Information and Energy Materials, Pusan National University, Busandaehakro 63-2, Busan, 46241, Republic of Korea.

Published: July 2020

Although Raman spectroscopy is a major analytical tool in modern chemical experiments, commercial Raman spectrometers remain very pricey for educational and research purposes in individual university laboratories. Thus, this study focused on the structural similarity between the Raman spectrometer and an optical pickup unit (OPU), which is an inexpensive compact optical device used for a part of optical discs. The study investigated whether or not a full set of Raman spectrometer can be developed at a cost of less than 1,000 US$. The OPU-based Raman spectrometer was fabricated using 3D printer-made components, a Raman edge filter, and a laser diode with a wavelength of 520 nm as the light source. A function generator was used as a pulsed power source to analyze the characteristics of the OPU Raman spectrometer according to various frequencies and duty ratios. When using a pulsed DC power supply, the laser wavelength tended to move to a longer wavelength with increases in duty ratios. That is, the higher the frequency at the same duty ratio, the weaker the background light intensity compared with the scattered Raman signal intensity. The findings illustrate that Raman signal strength can be adjusted by adjusting the focal length of the objective lens of the OPU through an external adjustment of an additional DC power. In the Raman spectra of all solid and liquid samples used, the maximum error rate reached approximately 11 cm, whereas the maximum intensity deviation reached approximately ± 6%. The cost of the complete OPU Raman spectrometer is less than 1,100 US$ using a function generator as power source and less than 930 US$ using a DC adapter. If the optical density (OD) 6 filter can be replaced with the OD 4 filter, then the costs are expected to decrease to approximately 730 US$.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7366627PMC
http://dx.doi.org/10.1038/s41598-020-68650-7DOI Listing

Publication Analysis

Top Keywords

raman spectrometer
24
pulsed power
12
raman
11
spectrometer optical
8
optical pickup
8
pickup unit
8
power raman
8
function generator
8
power source
8
opu raman
8