Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To validate the diagnostic accuracy of a previously described short sonographic protocol to identify chronic inflammatory neuropathy (CIN), including chronic inflammatory demyelinating polyneuropathy (CIDP), Lewis Sumner syndrome, and multifocal motor neuropathy (MMN), and to determine the added value of nerve ultrasound to detect treatment-responsive patients compared to nerve conduction studies (NCS) in a prospective multicenter study.
Methods: We included 100 consecutive patients clinically suspected of CIN in 3 centers. The study protocol consisted of neurologic examination, laboratory tests, NCS, and nerve ultrasound. We validated a short sonographic protocol (median nerve at forearm, upper arm, and C5 nerve root) and determined its diagnostic accuracy using the European Federation of Neurological Societies/Peripheral Nerve Society criteria of CIDP/MMN (reference standard). In addition, to determine the added value of nerve ultrasound in detecting treatment-responsive patients, we used previously published diagnostic criteria based on clinical, NCS, and sonographic findings and treatment response (alternative reference standard).
Results: Sensitivity and specificity of the sonographic protocol for CIN according to the reference standard were 87.4% and 67.3%, respectively. Sensitivity and specificity of this protocol according to the alternative reference standard were 84.6% and 72.8%, respectively, and of NCS 76.1% and 93.4%. With addition of nerve ultrasound, 44 diagnoses of CIN were established compared to 33 diagnoses with NCS alone.
Conclusions: A short sonographic protocol shows high diagnostic accuracy for detecting CIN. Nerve ultrasound is able to detect up to 25% more patients who respond to treatment.
Classification Of Evidence: This multicenter study provides Class IV evidence that nerve ultrasound improves diagnosis of CIN.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1212/WNL.0000000000010369 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!