Background: Cardiac implantable electronic devices (CIED) are sometimes required after alcohol septal ablation (ASA) for hypertrophic cardiomyopathy (HCM). The primary objectives of this study were to characterize the incidence, timing, and predictors of CIED placement after ASA for HCM.

Methods: Patients were identified from the 2010-2015 Nationwide Readmissions Databases. Incidence, timing and independent predictors of CIED placement, as well as 30-day readmission rates were examined.

Results: There were 1296 patients (national estimate = 2864) with HCM who underwent ASA. CIED were implanted in 322 (25% overall; 14% permanent pacemaker, 11% implantable cardioverter defibrillator) during the index hospitalization. Of these, 21%, 23%, 21%, and 18% occurred on postprocedure day 0, 1, 2, and 3, respectively. Only 17 (1.3%) patients underwent CIED implantation between discharge and 30-day follow up. Independent predictors of index hospitalization CIED implantation included older age, diabetes, heart failure, nonelective index hospital admission and hospitalization at a privately owned hospital. Nonelective 30-day readmission rates among those who did and did not undergo CIED placement during their index hospitalization, were 6.8% and 7.9%, respectively (p = .53); median time to readmission was also similar between groups.

Conclusions: One in four HCM patients undergoing ASA underwent CIED implantation during their index hospitalization; nearly 2/3rd during the first 48 h postprocedure. Private hospital ownership independently predicted CIED placement. More data are needed to better understand the unexpectedly high rates of CIED placement, earlier than anticipated timing of implantation and differential rates by hospital ownership.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.14679DOI Listing

Publication Analysis

Top Keywords

cied placement
20
cied implantation
12
cied
10
cardiac implantable
8
implantable electronic
8
alcohol septal
8
septal ablation
8
hypertrophic cardiomyopathy
8
incidence timing
8
predictors cied
8

Similar Publications

Temporary Transvenous Pacing Performed in the Intensive Care Unit or in the Catheterization Laboratory.

Pacing Clin Electrophysiol

January 2025

Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.

Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.

Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.

View Article and Find Full Text PDF

Introduction: Ultrasound (US)-guided axillary vein puncture is a safe and effective approach for cardiac implantable electronic device (CIED) implantation, and it is highly recommended by the current consensus document. However, only reports on small populations are available in the current literature regarding the comparison of this technique with other traditional approaches (subclavian vein blind puncture and cephalic vein surgical cutdown).

Purpose: We aimed to assess the effectiveness and safety of US- guided axillary vein puncture using a microintroducer kit for CIED implantation as compared to the aforementioned traditional approaches.

View Article and Find Full Text PDF

The placement of cardiovascular implantable electronic devices (CIED) comes with a risk of adverse events (AE). AE comprise complications associated with the procedure and the device. CIED infection is a severe AE.

View Article and Find Full Text PDF
Article Synopsis
  • Ultrasound-guided axillary (USAX) vein puncture is a newer technique for accessing veins during cardiac device implantation but is underused due to a lack of familiarity among operators.
  • A study compared USAX with traditional cephalic vein access in 114 patients, focusing on successful lead placement and procedure-related metrics.
  • Results showed USAX had a higher success rate, shorter procedure time, and less pain compared to the cephalic method, with similar complication rates overall.
View Article and Find Full Text PDF

Aims: The use of ultrasound (US)-guided venous puncture for cardiac pacing/defibrillation lead placement may minimize the risk of periprocedural complications and radiation exposure. However, none of the published studies have been sufficiently powered to recommend this approach as the standard of care. We compare the safety and efficacy of ultrasound-guided axillary venous puncture (US-AVP) vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!