A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Using a Modified CPD Blood Bag to Store Blood from either ECMO or RRT Circuit Blood in Pediatric Patients. | LitMetric

Using a Modified CPD Blood Bag to Store Blood from either ECMO or RRT Circuit Blood in Pediatric Patients.

J Extra Corpor Technol

Department of Cardiac Surgery, Department of Nursing, Department of Anesthesiology and Critical Care Medicine, and Division of Pediatric Nephrology, Mayo Clinic, Rochester, Minnesota.

Published: June 2020

By adapting a citrate phosphate dextrose (CPD) whole blood storage bag, residual blood from a renal replacement therapy (RRT) circuit can be saved in pediatric patients, decreasing in donor exposure later. The techniques used for autologous preoperative blood storage are the basis of storing the RRT circuit blood. The CPD anticoagulant has a benefit of having a commonly used reversal agent for its anticoagulant properties, i.e., calcium. Also, unlike the traditional anticoagulants used in extracorporeal membrane oxygenation (ECMO), i.e., heparin, and direct thrombin inhibitors, i.e., bivalirudin, there is no increase in anticoagulation laboratory parameters after administration. The CPD volume in the bag is reduced but keeps the original ratio the same between CPD and blood. This is accomplished by removing all CPD from the bag, adding back only the exact amount of CPD needed for the smaller amount of blood being transferred from the circuit. The RRT circuit managed at our institution uses 23 mL of CPD for 165 mL of circuit blood when stored with this technique. This calculation assumes a normal patient calcium level. This technique has been used successfully multiple times in more than 30 pediatric patients without incident for 7 years at our center. The CPD bag can also be used to store the residual blood from ECMO circuits after removal of ECMO to allow the blood to be given back to the patient at a later time by keeping the same citrate-to-blood ratio.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7332168PMC
http://dx.doi.org/10.1182/ject-2000017DOI Listing

Publication Analysis

Top Keywords

rrt circuit
16
blood
12
cpd blood
12
circuit blood
12
pediatric patients
12
bag store
8
blood ecmo
8
cpd
8
blood storage
8
residual blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!