The design of feasible trajectories to traverse the k-space for sampling in magnetic resonance imaging (MRI) is important while considering ways to reduce the scan time. Over the recent years, non-Cartesian trajectories have been observed to result in benign artifacts and being less sensitive to motion. In this paper, we propose a generalized framework that encompasses projection-based methods to generate feasible non-Cartesian k-space trajectories. This framework allows to construct feasible trajectories from both random or structured initial trajectories, e.g., based on the traveling salesman problem (TSP). We evaluate the performance of the proposed methods by simulating the reconstruction of 128 × 128 and 256 × 256 phantom and brain MRI images in terms of structural similarity (SSIM) index and peak signal-to-noise ratio (PSNR) using compressed sensing techniques. It is observed that the TSP-based trajectories from the proposed projection method with constant acceleration parameterization (CAP) result in better reconstruction compared to the projection method with constant velocity parameterization (CVP) and this for a similar read-out time. Further, random-like trajectories are observed to be better than TSP-based trajectories as they reduce the read-out time while providing better reconstruction quality. A reduction in read-out time by upto 67% is achieved using the proposed projection with permutation (PP) method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2020.06.016DOI Listing

Publication Analysis

Top Keywords

read-out time
12
trajectories
9
k-space trajectories
8
feasible trajectories
8
trajectories observed
8
tsp-based trajectories
8
proposed projection
8
projection method
8
method constant
8
better reconstruction
8

Similar Publications

NeuroCarto: A Toolkit for Building Custom Read-out Channel Maps for High Electrode-count Neural Probes.

Neuroinformatics

January 2025

Neuro Electronics Res. Flanders (NERF), Heverlee, 3001, Belgium.

Neuropixels probes contain thousands of electrodes across one or more shanks and are sufficiently small to allow chronic recording of neural activity in freely behaving small animals. However, the joint increase in the number of electrodes and miniaturization of the probe package has led to a compromise in which groups of electrodes share a single read-out channel and only a fraction of the electrodes can be read out at any given time. Experimenters then face the challenge of selecting a subset of electrodes (i.

View Article and Find Full Text PDF

Background: Immune correlates of protection are ideal tools to predict treatment or vaccine efficacy. However, the accuracy of the immune correlate and the capability to robustly predict the outcome of a vaccine candidate are determined by the performance of the in vitro immunoassay used. Several sporozoite seroneutralization assays have previously been used to assess antibody functional activities; however, a common limitation has been the need for fresh material, target cells and sporozoites, and operator-to-operator bias.

View Article and Find Full Text PDF

Free-choice behavior is unique in that actions are internally self-determined, unlike forced-choice behavior, which is externally specified. Several studies suggest these two action modes can lead to different behavioral, affective, and motivational outcomes. We examined whether people estimate free-choice differently from forced-choice processing time due to possible introspective biases associated with these modes.

View Article and Find Full Text PDF

Eco-sustainable point-of-care devices: Progress in paper and fabric based electrochemical and colorimetric biosensors.

Talanta

December 2024

Department of Sensor and Biomedical Technology, School of Electronics Engineering (SENSE), Vellore Institute of Technology, Vellore, 632014, India. Electronic address:

Monitoring real-time health conditions is a rinsing demand in a pandemic prone era. Wearable Point-of-Care (POC) devices with paper and fabric-based sensors are emerging as simple, low-cost, portable, and disposable analytical tools for development of green POC devices (GPOCDs). Capabilities of passive fluid transportation, compatibility with biochemical analytes, disposability and high degree of tunability using vivid device fabrication strategies enables development of highly sensitive and economically feasible POC sensors in particularly post COVID-19 pandemic outbreak.

View Article and Find Full Text PDF

Time resolution is crucial in positron emission tomography (PET) to enhance the signal-to-noise ratio and image quality. Moreover, high sensitivity requires long scintillators, which can cause distortions in the reconstructed images due to parallax effects. This study evaluates the performance of a time-of-flight (TOF)-PET module that makes use of a single-side readout of a 4x4 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!