Objective: To evaluate the effectiveness of the different formulas for estimating the insertion depth of an endotracheal tube in children.

Methods: This was an observational and cross-sectional study that included children between 29 days and 2 years of age who were hospitalized in a pediatric intensive care unit and mechanically ventilated. The formulas based on height [(height/10) + 5], the inner diameter of the tube (endotracheal tube × 3), and weight (weight + 6) were evaluated to determine which of them showed better concordance with the ideal insertion depth of the endotracheal tube as evaluated by X-ray.

Results: The correlation between the height-based calculation and the ideal depth observed on X-ray was strong, with r = 0.88, p < 0.05, and a concordance correlation coefficient of 0.88; the correlation between the weight-based calculation and depth on X-ray was r = 0.75, p < 0.05, and concordance correlation coefficient 0.43; and the correlation between endotracheal tube diameter-based calculation and depth on X-ray was r = 0.80, p < 0.05, and concordance correlation coefficient 0.78. Lin's concordance correlation analysis indicated that the measurements showed weak concordance (< 0.90).

Conclusion: The formulas that estimate the insertion depth of the endotracheal tube in children were not accurate and were discordant with the gold-standard method of X-ray evaluation. There is a need for a new method based on anthropometric variables (weight and height) and age that is effective in guiding health professionals of pediatric intensive care units at the time of intubation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7405750PMC
http://dx.doi.org/10.5935/0103-507x.20200046DOI Listing

Publication Analysis

Top Keywords

endotracheal tube
24
insertion depth
16
concordance correlation
16
depth endotracheal
12
005 concordance
12
correlation coefficient
12
concordance ideal
8
pediatric intensive
8
intensive care
8
calculation depth
8

Similar Publications

: To compare tracheal temperature (T) with nasopharyngeal temperature (T) in patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). : T was measured using a thermistor in the cuff of an endotracheal tube and T was monitored using an esophageal stethoscope. Depending on the management of the CPB strategy, the operation was divided into four periods (pre-CPB, cooling, rewarming, and post-CPB).

View Article and Find Full Text PDF

Complex biological systems undergo sudden transitions in their state, which are often preceded by a critical slowing down of dynamics. This results in longer recovery times as systems approach transitions, quantified as an increase in measures such as the autocorrelation and variance. In this study, we analysed paediatric patients in intensive care for whom mechanical ventilation was discontinued through removal of the endotracheal tube (extubation).

View Article and Find Full Text PDF

Background: Bacterial lower respiratory tract infection, particularly ventilator-associated pneumonia (VAP), is a significant cause of morbidity and mortality in children who require mechanical ventilation (MV). Microbiologic diagnosis has relied on bacterial culture, but reverse transcriptase polymerase chain reaction (RT-PCR) with bacterial targets is now available for clinical use. We compared the diagnostic performance of tracheal aspirate (TA) multiplex RT-PCR to culture in children requiring MV with suspected lower respiratory tract infection.

View Article and Find Full Text PDF

Background: Various painful therapeutic and diagnostic procedures are performed daily for hospitalized infants. These procedures are very effective in their growth and recovery process. This study was conducted to determine "the frequency and pain intensity of painful procedures in premature infants hospitalized in NICU.

View Article and Find Full Text PDF

Introduction: Endotracheal tubes (ETT) are used in patients who require ventilatory support. Colonization of ETTs by microorganisms is associated with developing ventilator-associated pneumonia (VAP). Thus, this meta-analysis aims to compare conventional endotracheal tubes with those made using materials designed to prevent colonization.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!