In lipidomic analysis by direct mass spectrometry (MS), high abundance lipids with high ionizability (such as glycerophospholipids) would cause ion suppression to lipids with poor ionizability and low abundance (such as glycolipids, sphingolipids, or glycerides), which largely limits the detection coverage for lipidomics. In this work, TiO-based liquid microjunction surface sampling (LMJSS) coupled with MS was used for separation of glycerides, phospholipids and glycolipids/sphingolipids in biological samples and rapid analysis of lipids in different classes with high lipidome coverage. We found that, in nonaqueous aprotic solvents, lipids with a glycosyl or sphingosine group could be selectively separated from lipids with a phosphate group (selectivity >10) after being coenriched on TiO by tuning the solvent composition. Accordingly, a selective multistep extraction method was developed by loading the biosamples on TiO slides in neutral aprotic solvent, and sequentially eluting glycerides in pure acetonitrile, glycerophospholipids in 6% ammonia-94% acetonitrile () and glycolipids/sphingolipids in 5% formic acid-95% methanol (/) by LMJSS probe from TiO slide. Each eluate from TiO slide was directly delivered by LMJSS to MS for analysis. The total detection time with three desorption steps would be controlled in 3 min. The method performance for each lipid class was evaluated using lipid standards, including matrix effects (107-128%), RSDs (0.4-16%), linearity (0.98-0.99), detection limits (5-3000 ng/mL), the adsorption equilibrium constants (10-10) and adsorption capacity (1-38 μg/mm) of TiO coated slides to lipids. Finally, the TiO-based-LMJSS-MS method was applied to lipidomic analysis for blood plasma and brain tissue, and compared with direct infusion MS. Results showed that (2-5)-fold more sphingolipids/glycolipids and 40-50 more glycerophospholipids/glycerides were identified in both plasma and brain extract by the new method comparing with direct infusion MS method. Detected lipids were quantified with standard addition calibration method, and the absolute quantitation results measured by TiO-based-LMJSS-MS were verified with that by the traditional LC-MS method (correlation coefficient >0.98, slope of correlation line = 0.87-1.05).

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.0c01870DOI Listing

Publication Analysis

Top Keywords

lipidomic analysis
12
aprotic solvent
8
liquid microjunction
8
microjunction surface
8
tio slide
8
plasma brain
8
direct infusion
8
lipids
7
method
7
tio
6

Similar Publications

Combined Analysis of the Leaf Metabolome, Lipidome, and Candidate Gene Function: Insights into Genotypic Variation in Phosphorus Utilization Efficiency in .

J Agric Food Chem

January 2025

School of Tropical Agriculture and Forestry & Sanya Institute Breeding and Multiplication, Hainan University, Haikou/Sanya 570228/572025, China.

Stylo () exhibits excellent tolerance to low-phosphate (Pi) availability, but the underlying mechanisms responsible for improving the phosphorus (P) utilization efficiency (PUE) remain unclear. This study employed metabolomics, lipidomics, and gene expression analyses to investigate the differential responses to low-Pi stress between the high-PUE genotype CF047827 and the cultivar Reyan No. 2.

View Article and Find Full Text PDF

Ion mobility spectrometry and ion mobility-mass spectrometry in clinical chemistry.

Adv Clin Chem

January 2025

Department of Chemistry, Center for Innovative Technology, Institute of Chemical Biology, Institute for Integrative Biosystems Research and Education, Vanderbilt-Ingram Cancer Center, Vanderbilt University, Nashville, TN, United States. Electronic address:

Advancements in clinical chemistry have major implications in terms of public health, prompting many clinicians to seek out chemical information to aid in diagnoses and treatments. While mass spectrometry (MS) and hyphenated-MS techniques such as LC-MS or tandem MS/MS have long been the analytical methods of choice for many clinical applications, these methods routinely demonstrate difficulty in differentiating between isomeric forms in complex matrices. Consequently, ion mobility spectrometry (IM), which differentiates molecules on the basis of size, shape, and charge, has demonstrated unique advantages in the broad application of stand-alone IM and hyphenated IM instruments towards clinical challenges.

View Article and Find Full Text PDF

Double bond (C═C) position isomerism in unsaturated lipids can indicate abnormal lipid metabolism and pathological conditions. Novel chemical derivatization and mass spectrometry-based techniques are under continuing development to provide more accurate elucidation of lipid structure in finer structural detail. Here, we introduce a new ion chemistry for annotating lipid C═C positions, which is highly efficient for liquid chromatography-mass spectrometry-based lipidomics.

View Article and Find Full Text PDF

Background: Some studies suggest a potential association between plasma lipidome and erectile dysfunction (ED), but the underlying mechanism and whether circulating inflammatory proteins act as mediators remain unclear. The purpose of this study was to investigate the potential causal relationships between plasma lipidome, inflammatory proteins, and ED.

Methods: Plasma lipidome, circulating inflammatory proteins, and ED cases were identified based on the summary data from several large-scale genome-wide association studies (GWAS).

View Article and Find Full Text PDF

Single cell lipid biology.

Trends Cell Biol

January 2025

Institute of Bioengineering (IBI) and Global Health Institute, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland. Electronic address:

Lipids are major cell constituents endowed with astonishing structural diversity. The pathways responsible for the assembly and disposal of different lipid species are energetically demanding, and genes encoding lipid metabolic factors and lipid-related proteins comprise a sizable fraction of our coding genome. Despite the importance of lipids, the biological significance of lipid structural diversity remains largely obscure.

View Article and Find Full Text PDF