A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 144

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 144
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 212
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1002
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3142
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a re-engineered device for penile vibratory stimulation in men with spinal cord injury. | LitMetric

Study Design: Cohort study OBJECTIVES: The purpose of this study was to evaluate the performance of a re-engineered device (Ferticare 2.0), which is replacing the previous standard (Ferticare 1.0) for penile vibratory stimulation in men with spinal cord injury. Most men with spinal cord injury are anejaculatory, requiring medical assistance to obtain their semen. Penile vibratory stimulation is generally recognized as the standard of care for semen retrieval in these anejaculatory men.

Setting: Major Research University in Miami, Florida, USA.

Methods: The Ferticare 2.0 device was applied to 15 men with spinal cord injury in a three-step protocol simulating normal use. Step 1: one device (2.5 mm amplitude, 100 Hz) was applied to the glans penis for 2 min. Step 2: If no ejaculation occurred, the amplitude was increased to 4.0 mm (100 Hz) and the device similarly applied. Step 3: If no ejaculation occurred, two devices, each 2.5 mm and 100 Hz were applied to the dorsum and frenulum of the glans penis. Participants at risk for autonomic dysreflexia were pretreated with sublingual nifedipine (20 mg), 15 min prior to stimulation. Blood pressure and other symptoms of autonomic dysreflexia were monitored. Participants answered a questionnaire about their experience with the device.

Results: Thirteen of 15 participants ejaculated with the device. No adverse events occurred. All participants commented they would recommend the device to other men with spinal cord injury.

Conclusions: A re-engineered device, the Ferticare 2.0, is safe and effective for inducing ejaculation in men with spinal cord injury.

Download full-text PDF

Source
http://dx.doi.org/10.1038/s41393-020-0515-6DOI Listing

Publication Analysis

Top Keywords

men spinal
24
spinal cord
24
cord injury
20
re-engineered device
12
penile vibratory
12
vibratory stimulation
12
device
8
stimulation men
8
device ferticare
8
device applied
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!