Harnessing the energy of tidal currents has huge potential as a source of clean renewable energy. To do so in a reliable and cost effective way, it is critical to understand the interaction between tidal turbines, waves, and turbulent currents in the ocean. Scaled testing in a tank test provides a controlled, realistic, and highly reproducible down-scaled open ocean environment, and it is a key step in gaining this understanding. Knowledge of the hydrodynamic conditions during tests is critical and measurements at multiple locations are required to accurately characterise spatially varying flow in test tank facilities. The paper presents a laboratory technique using an acoustic velocimetry instrument, the range over-which measurements are acquired being more akin to open water applications. This enables almost simultaneous multi-point measurements of uni-directional velocity along a horizontal profile. Velocity measurements have been obtained from a horizontally mounted Single Beam Acoustic Doppler (SB-ADP) profiler deployed in the FloWave Ocean Energy Research Facility at the University of Edinburgh. These measurements have been statistically compared with point measurements obtained while using a co-located Acoustic Doppler Velocimeter (ADV). Measurements were made with both instruments under flow velocities varying from 0.6 ms to 1.2 ms, showing that flow higher than 1 ms was more suitable. Using a SB-ADP has shown the advantage of gaining 54 simultaneous measurement points of uni-directional velocity, covering a significant area with a total distance of 10 m of the test-tank, at a measurement frequency of 16 Hz. Of those measurement points, 41 were compared with co-located ADV measurements covering 8 m of the profile for a tank nominal flow velocity of 0.8 ms, and four distributed locations were chosen to to carry out the study at 0.6 ms, 1.0 ms, and 1.2 ms. The comparison with the ADV measurement showed a 2% relative bias on average.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7411848PMC
http://dx.doi.org/10.3390/s20143881DOI Listing

Publication Analysis

Top Keywords

single beam
8
beam acoustic
8
measurements
8
uni-directional velocity
8
acoustic doppler
8
adv measurements
8
measurement points
8
velocity
5
measurement
5
acoustic
4

Similar Publications

Background And Purpose: In proton therapy, a relative biological effectiveness (RBE) of 1.1 is used to convert proton dose into an equivalent photon dose. However, RBE varies with tissue type, fraction dose, and beam quality parameters beyond dose such as linear energy transfer (LET) raising concerns about increased local effectiveness and potential toxicity.

View Article and Find Full Text PDF

Sparse loudspeaker array design for wideband frequency-invariant beamforming with multiple targets.

J Acoust Soc Am

January 2025

Key Laboratory of Modern Acoustics, Institute of Acoustics, Nanjing University, Nanjing 210093, China.

Beamforming technology using loudspeaker arrays is widely used in sound applications, but current sparse array design methods focus on optimizing a single beam for a single target direction, limiting their applicability to multi-channel sound systems. This paper presents a design method for sparse loudspeaker line arrays to generate wideband frequency-invariant beams in multiple target directions. A model based on tapped delay lines is developed and a two-stage design approach is proposed.

View Article and Find Full Text PDF

The field of chiral nanoparticles is rapidly expanding, yet measuring the chirality of single nano-objects remains a challenging endeavor. Here, we report a technique to detect chiro-optical effects in single plasmonic nanoparticles by means of phase-sensitive polarization-resolved four-wave mixing interferometric microscopy. Beyond conventional circular dichroism, the method is sensitive to the particle polarizability, in amplitude and phase.

View Article and Find Full Text PDF

Root canal retreatment (Re-RCT) cases have shortcomings due to the ineffective removal of the root canal filling material, eventually leading to endodontic failure. This study aims to test the comparative efficacy of retreatment files in removing calcium silicate-based sealer and epoxy resin-based sealer. Thirty-two single-rooted teeth were decoronated at 15 mm and bio-mechanical preparation was performed.

View Article and Find Full Text PDF

Introduction: Dental implants are the most popular alternative to rehabilitation of missing teeth and oro-facial structures. The outcome of such procedures depends on various factors and most-importantly on the osseo-integation with the surrounding bone. The evaluation needs better visualization and evaluation using CBCT anaylsis and determination of HU, using an appropriate software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!