Xerostomia is a symptom frequently present in patients with type 1 (T1DM) and type 2 diabetes mellitus (T2DM). In the present trial, the activity of an artificial saliva (aldiamed spray) in comparison to a placebo spray were used to evaluate the xerostomia and the saliva antioxidant capacity (SAT). Sixty patients of both genders with T1DM or T2DM were randomized into two groups of 30 subjects each. The experiment was a double-blind study approved by the Ethics Committee of the "G. d'Annunzio University" of Chieti and Pescara. Moreover, measurements of the stimulated saliva flow rate and the ultrasonography of the submandibular and parotid glands were performed at both the study time points. The results demonstrated statistically significant differences between the treatments in terms of the xerostomia average score. Specifically, the values were at baseline and after 30 days 2.9 ± 1.31 and 3.0 ± 1.44 and 1.4 ± 1.48 and 2.4 ± 0.99 for aldiamed spray and the placebo, respectively. Meanwhile, no statistically significant differences were shown between the two groups for the other variables, such as the salivary flow rate, the antioxidant capacity of the saliva, and the ultrasonography of the major salivary glands.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7408818PMC
http://dx.doi.org/10.3390/jcm9072196DOI Listing

Publication Analysis

Top Keywords

artificial saliva
8
aldiamed spray
8
antioxidant capacity
8
flow rate
8
statistically differences
8
saliva diabetic
4
xerostomia
4
diabetic xerostomia
4
xerostomia asdix
4
asdix double
4

Similar Publications

Conductive and flexible gold-coated polylactic acid nanofiber-based electrochemical aptasensor for monitoring cortisol level in sweat and saliva.

Bioelectrochemistry

January 2025

Department of Bioengineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo 113-8656, Japan. Electronic address:

Conductive nanofibers can exhibit excellent mechanical properties such as flexibility, elasticity, porosity, large surface area-to-volume ratio, etc making them suitable for a wide range of applications including biosensor development. Their large surface area provides more active sites for immobilization of large amount of bioreceptors enabling more interaction sites with the target analytes, enhancing sensitivity and detection capabilities. However, engineering conductive nanofibers with such excellent properties is challenging limiting their effective deployment for intended applications.

View Article and Find Full Text PDF

Rapid identification of pathogenic bacteria from clinical positive blood cultures virus-like magnetic bead enrichment and MALDI-TOF MS profiling.

Analyst

January 2025

Institutes of Biomedical Sciences & Shanghai Stomatological Hospital, Department of Chemistry, Fudan University, Shanghai 200433, China.

Reducing the time required for the detection of bacteria in blood samples is a critical area of investigation in the field of clinical diagnosis. Positive blood culture samples often require a plate culture stage due to the interference of blood cells and proteins, which can result in significant delays before the isolation of single colonies suitable for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis. In this study, we developed a non-specific enrichment strategy based on SiO-encapsulated FeO nanoparticles combined with MALDI-TOF MS for direct identification of bacteria from aqueous environments or positive blood culture samples.

View Article and Find Full Text PDF

Virus-laden aerosols play a substantial role in the spread of numerous infectious diseases, particularly in enclosed indoor settings. Ultraviolet-C (UVC) disinfection is known to be a highly efficient method for disinfecting pathogenic airborne viruses. Recent recommendations suggest using far-UVC radiation (222 nm) emitted by KrCl* (krypton-chloride) excimer lamps to disinfect high-risk public spaces due to lower exposure risks than low-pressure (LP) mercury lamps (254 nm).

View Article and Find Full Text PDF

Prenatal sonographic diagnosis of congenital heart disease (CHD) can lead to improved morbidity and mortality. However, the diagnostic accuracy of ultrasound, the sole prenatal screening tool, remains limited. Failed prenatal or early newborn detection of cyanotic CHD (CCHD) can have disastrous consequences.

View Article and Find Full Text PDF

Photonic crystal-based aptasensors for viral proteins detection offer the advantage of producing visible readouts. However, they usually suffer from limited sensitivity and high non-specific background noise. A significant contributing factor to these issues is the use of fixed-conformation aptamers in these sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!