Purpose: Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7-11 years.
Methods: We retrospectively evaluated 240 consecutive hips that received cementless THA using the same dual mobility cup (Novae Sunfit TH) and femoral stem (Corail). Patients were recalled at ≥7 years to collect Oxford hip scores (OHS), Harris hip scores (HHS), and inspect for radiolucent lines and granulomas. Multi-variable analyses were performed to determine whether HHS or OHS were associated with pre- or intra-operative variables.
Results: At 8.4 ± 0.8 years (range, 7-11), 6 hips were revised (2.5%), 54 deceased (22.5%), and 14 could not be reached (5.8%). Four revisions (2 cup+stem, 2 liners only) were due to sepsis (1.7%), one (cup and stem) for trauma (0.4%), and one (stem) due to aseptic loosening (0.4%). For the remaining 166 hips, HHS was 83.6 ± 13.2 and OHS was 20.3 ± 6.7. Multi-variable analysis confirmed that HHS (β = - 0.38; p = 0.039) and OHS (β = 0.36; p < 0.001) worsened with age, and that OHS was worse for Charnley C patients (β = 3.17; p = 0.009). Neither granulomas nor radiolucenies were observed around any cups, but radiolucenies were seen around 25 stems (20.3%).
Conclusions: This fourth-generation DM cup demonstrated satisfactory outcomes at 7-11 years, with no instabilities or cup revisions due to aseptic loosening. Better OHS was observed for younger patients and those presenting higher Charnley grade.
Level Of Evidence: Level IV, retrospective case study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359208 | PMC |
http://dx.doi.org/10.1186/s40634-020-00265-3 | DOI Listing |
Orthop Surg
May 2022
Department of Orthopeadics, The First Medical Centre, Chinese PLA General Hospital, Beijing, China.
Objective: To report the long-term outcomes of total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearing in patients with ankylosing spondylitis (AS).
Methods: We retrospectively identified 180 primary THAs performed in 110 patients with AS, including 100 (90.9%) men and 10 women (9.
J Clin Med
September 2021
Laboratory of Biomechanics and Implant Research, Clinic for Orthopaedics and Trauam Surgery, Heidelberg University Hospital, 69118 Heidelberg, Germany.
The goal of this study is to evaluate the primary stability of a cementless augment-and-modular-cage system with and without the addition of cranial straps in a standardized in vitro setting. As the surrogate parameter for the evaluation of primary stability, the measurement of relative motion between the implant components themselves and the bone will be used. Acetabular revision components with a trabecular titanium augment in combination with a large fourth-generation composite left hemipelvis were assembled.
View Article and Find Full Text PDFPurpose: Dual-mobility (DM) cups are increasingly used in total hip arthroplasty (THA) but there lacks literature on their long-term results. We aimed to investigate outcomes of a fourth-generation cementless DM acetabular cup at 7-11 years.
Methods: We retrospectively evaluated 240 consecutive hips that received cementless THA using the same dual mobility cup (Novae Sunfit TH) and femoral stem (Corail).
Acta Biomed
May 2020
Department of Orthopaedic and Trauma Surgery, University of Verona, Italy.
Fourth generation ceramic bearings (BIOLOX delta, CeramTec AG; Phlochingen, Germany) were developed to reduce wear debris and improve fracture resistance. A case of a fourth generation head fracture in ceramic-on-polyethylene (COP) coupling after hip revision surgery is reported. A 58-year-old man was admitted to our department for increasing hip pain following a direct trauma which occurred during skiing activity 4 months before.
View Article and Find Full Text PDFBone Joint Res
October 2019
Orthomedic Frankfurt Offenbach, Offenbach, Germany.
Objectives: Periprosthetic femoral fractures (PFFs) have a higher incidence with cementless stems. The highest incidence among various cementless stem types was observed with double-wedged stems. Short stems have been introduced as a bone-preserving alternative with a higher incidence of PFF in some studies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!