Despite that Hyperbolic Metamaterial (HMM) has demonstrated sub-wavelength focusing inside of it, sub-wavelength imaging in free space of HMM is rarely introduced. The decay of hyperbolic momentum space outside the hyperbolic medium has hindered the realization of sub-wavelengh focusing in the near field of HMM. Furthermore, manipulating the negatively refracted waves exiting the HMM have addressed another major obstacle to realize free space sub-wavelength focusing. In this work, we report extended sub-wavelength focusing in free space based on negative refraction of light exiting the HMM. The proposed structure is composed of multilayers of doped InAs/intrinsic InAs integrated with metallic slit. We theoretically simulate the doped InAs/intrinsic InAs HMM and investigate the negative refraction behavior outside the HMM. We optimized the structure for achieving high resolution down to 0.2λ, extended to a distance of 3.2 µm in free space. Also, sub-wavelength focusing in free space has been studied at different doping concentrations showing that the small doping concentrations exhibit enhancement in resolution at short distances up to 600 nm away from the HMM. Extending the focusing distance is achieved up to distance 3.5 µm from the hyperbolic structure by manipulating the doping concentration. This proposed lens configuration is expected to find potential usage in mid IR thermal imaging and photolithography application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7359356PMC
http://dx.doi.org/10.1038/s41598-020-61639-2DOI Listing

Publication Analysis

Top Keywords

free space
24
sub-wavelength focusing
16
hyperbolic metamaterial
8
hmm
8
exiting hmm
8
space sub-wavelength
8
focusing free
8
negative refraction
8
doped inas/intrinsic
8
inas/intrinsic inas
8

Similar Publications

Purpose: Fluid exchanges between perivascular spaces (PVS) and interstitium may contribute to the pathophysiology of small vessel disease (SVD). We aimed to analyze water diffusivity measures and their relationship with PVS and other SVD imaging markers.

Methods: We enrolled 50 consecutive patients with a recent small subcortical infarct.

View Article and Find Full Text PDF

The study of transient and variable events, including novae, active galactic nuclei, and black hole binaries, has historically been a fruitful path for elucidating the evolutionary mechanisms of our universe. The study of such events in the millimeter and submillimeter is, however, still in its infancy. Submillimeter observations probe a variety of materials, such as optically thick dust, which are hard to study in other wavelengths.

View Article and Find Full Text PDF

Significance: Imaging flow cytometry allows highly informative multi-point cell analysis for biological assays and medical diagnosis. Rapid processing of the imaged cells during flow allows real-time classification and sorting of the cells. Off-axis holography enables imaging flow cytometry without chemical cell staining but requires digital processing to the optical path delay profile for each frame before the cells can be classified, which slows down the overall processing throughput.

View Article and Find Full Text PDF

Background: Short dentin etching, a relatively recent technique, aims to improve resin-dentin bonding by preserving hydroxyapatite crystals within the collagen spaces. This study explores short dentin etching's potential in mitigating over-etching issues in deep proximal dentin/cementum margins, an aspect not previously investigated. This study evaluates the microtensile bond strength (μTBS) and marginal adaptation of two universal adhesives using different etch-and-rinse strategies (15-second and 3-second etching) and self-etch strategies, both immediate and post-thermal cycling and mechanical loading.

View Article and Find Full Text PDF

Historically, electrophysiological correlates of scene processing have been studied with experiments using static stimuli presented for discrete timescales where participants maintain a fixed eye position. Gaps remain in generalizing these findings to real-world conditions where eye movements are made to select new visual information and where the environment remains stable but changes with our position and orientation in space, driving dynamic visual stimulation. Co-recording of eye movements and electroencephalography (EEG) is an approach to leverage fixations as time-locking events in the EEG recording under free-viewing conditions to create fixation-related potentials (FRPs), providing a neural snapshot in which to study visual processing under naturalistic conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!