Background: Point-of-care (POC) CD4+ technologies have the potential to increase patient access to treatment and care through rapid testing and result delivery at or close to where patients seek care. South African (SA) guidelines suggest the use of CD4+ testing to prioritise patients most in need of antiretroviral therapy (ART) and to support identification of patients with advanced HIV disease and opportunistic management of patients on ART. Understanding the patient impact of implementing POC CD4+ testing in the intended setting and operated by lower cadres of healthcare worker or non-professional healthcare facility staff will provide valuable insight into the appropriate use and placement of POC CD4+ technologies throughout SA.
Objectives: To determine the patient impact (turnaround time of tests, loss to follow-up, and proportions of eligible patients proceeding to the next steps in the testing and treatment cascade) of implementing POC CD4+ testing technologies compared with conventional laboratory-based CD4+ testing.
Methods: This retrospective cohort study included all HIV-positive adults from 30 healthcare facilities in Free State Province, SA. Healthcare facilities were placed into two groups (POC and laboratory referral) using a stratified randomisation technique based on the presence of a POC CD4+ technology and minimal ART volumes. Patients who received a CD4+ test prior to ART initiation between September 2012 and September 2014 were included. Data were collected from patient charts and the POC devices.
Results: For new patients, the average time from HIV diagnosis and CD4+ testing was reduced from 7.6 days in the laboratory referral group to 4.5 days in the POC group, a decrease of almost 60%. Additionally, 59.6% of patients in the POC group received their HIV diagnosis and CD4+ test result on the same day, compared with 37.5% in the laboratory referral group (risk ratio (RR) 1.49; 95% confidence interval (CI) 1.01 - 2.18). Fewer patients were lost between HIV diagnosis and CD4+ testing (2.7% v. 8.6%) (RR 0.02; 95% CI 0.05 - 0.78) in the POC group. The average test error rate across the study time period was 8.4%; however, the error rate remained <5% for the final 5 months of the study.
Conclusions: Introduction of the Alere Pima POC CD4+ technology in the Free State, operated by nurses and lay counsellors, was associated with positive patient outcomes across all parameters analysed. While this study highlighted an effective conventional laboratory network, a full costing and affordability analysis coupled with patient impact and access data from this study will provide further insight into the potential deployment strategies of POC CD4+ technologies in SA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7196/SAMJ.2020.v110i2.13823 | DOI Listing |
Medicina (Kaunas)
December 2024
Department of Biostatistics and Medical Informatics, Faculty of Medicine, Kocaeli University, Kocaeli 41001, Turkey.
: CD4+ T lymphocytes are the primary targets of HIV infection. CD4+ T lymphocyte count is an indicator of immune competence. In this study, we aimed to compare standard flow cytometry and point-of-care (POC) CD4+ T lymphocyte in terms of cost, effectiveness, reliability, time, and the use of this method for disease.
View Article and Find Full Text PDFMol Ther Oncol
December 2024
Siriraj Center of Excellence for Stem Cell Research, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand.
Anti-CD19 chimeric antigen receptor (CAR)-T cell therapy has evolved as a standard of care for various forms of relapsed/refractory B cell malignancies in major developed countries. However, access to industry-driven CAR-T cell therapy is limited in developing countries, partly due to the centralized manufacturing system. Here, we demonstrated the feasibility of the point-of-care (POC) manufacturing of anti-CD19 CAR-T cells from heavily pretreated patients and healthy graft donors at an academic medical center in Thailand using a closed semi-automated production platform, CliniMACS Prodigy, and established in-process quality control and release testing to ensure their identity, purity, sterility, safety, and potency.
View Article and Find Full Text PDFFront Immunol
October 2024
Institute of Cellular Therapeutics (ICT), Hannover Medical School (MHH), Hanover, Germany.
ACS Omega
June 2024
Translational Medicine Collaborative Innovation Center, The First Affiliated Hospital (Shenzhen People's Hospital), Southern University of Science and Technology, Shenzhen 518055, China.
Straightforward, sensitive, and specific human immunodeficiency virus (HIV) assays are urgently needed. The creation of a point-of-care (POC) device for decentralized diagnostics has the potential to significantly reduce the time to treatment, especially for infectious diseases. Notably, however, many POC solutions proposed to date fall short of meeting the ASSURED guidelines, which are crucial for effective deployment in the field.
View Article and Find Full Text PDFPLoS One
March 2024
Laboratory of Immunology, Faculty of Sciences, University of Rome "Tor Vergata", Rome, Italy.
Background: Measurements of CD4 T cells and hemoglobin (Hb) are conventionally used to determine the immunological state and disease progression for HIV-infected patients. We obtained a small lightweight point-of-care device, the BD FACSPrestoTM in order to demonstrate its ability to deliver CD4 and Hb analysis in comparison with two larger clinical machines the BDFACSCantoTM analyzer and Sysmex XN 1000 haematology analyzer. The advantages of using the POC device include access to HIV patient data in remote and in resource limited settings.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!