Objectives: Drug-laboratory test interactions (DLTIs) are one of the major sources of laboratory errors. Calcium dobesilate (CaD) interference on serum creatinine testing is a widespread problem that has long been ignored in China. A national EQA-based survey was launched to investigate the current status of CaD interference on creatinine routine methods used in China and enhance the education of CaD interference in clinical laboratories.

Methods: A descriptive survey was developed to characterize the status quo of Chinese laboratory professionals' cognition to CaD interference. Four of survey samples which were spiked with/without interference additive were shipped to 175 participant laboratories. The target reference values from a reference measurement procedure were compared against the results from participating laboratories to evaluate the CaD interference on serum creatinine measurements using enzymatic method or Jaffé method.

Results: The lack of knowledge of DLTIs and the barriers to collect information from pharmacological and laboratory data systems had become the main problems on implementing DLTIs education in China. A significant negative influence of CaD on enzymatic method was observed regardless of measurement platforms. Jaffé method was generally free from interaction with CaD but showed poor precision and accuracy at low creatinine concentrations.

Conclusions: More efforts should be made to enhance the education of DLTIs in clinical laboratories in China.

Download full-text PDF

Source
http://dx.doi.org/10.1515/cclm-2020-0424DOI Listing

Publication Analysis

Top Keywords

cad interference
24
interference serum
12
serum creatinine
12
calcium dobesilate
8
cad
8
dobesilate cad
8
creatinine measurements
8
drug-laboratory test
8
test interactions
8
enhance education
8

Similar Publications

Geometric description of a gliding grey-headed albatross () for computer-aided design.

Bioinspir Biomim

January 2025

Department of Mechanical and Aeronautical Engineering, University of Pretoria, 1 Lynnwood Road, Pretoria, 0002, SOUTH AFRICA.

Albatrosses are increasingly drawing attention from the scientific community due to their remarkable flight capabilities. Recent studies suggest that grey-headed albatrosses may be the fastest and most energy-efficient of the albatross species, yet no attempts have been made to replicate their wing design. A key factor in aircraft design is the airfoil, which remains uncharacterized for the grey-headed albatross.

View Article and Find Full Text PDF

Efficacy of Novel Digital-Based Surgical Guide in the Limited Interocclusal Distance.

Bioengineering (Basel)

November 2024

Department of Prosthodontics, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.

Accurate implant placement is essential for achieving successful outcomes. To aid in this, digitally designed surgical guides have been introduced. Both closed-sleeve and open-sleeve designs are commonly utilized.

View Article and Find Full Text PDF

Advancing 3D dental scanning: The use of photogrammetry with light detection and ranging for edentulous arches.

J Prosthet Dent

December 2024

Professor and Chair, Department of Restorative Dentistry, Rutgers School of Dental Medicine, Rutgers Biomedical and Health Sciences, Rutgers University, Newark, NJ.

Statement Of Problem: The advent of computer-aided design and computer-aided manufacturing (CAD-CAM) has necessitated the acquisition of digital scans. However, there are limitations and problems with acquiring accurate 3-dimensional (3D) casts from edentulous patients, especially in the presence of saliva.

Purpose: The purpose of this in vitro study was to develop a novel approach for obtaining 3D casts of edentulous arches by using 2-dimensional (2D) images as an alternative to traditional 3D scanners with and without light detection and ranging (LiDAR).

View Article and Find Full Text PDF
Article Synopsis
  • - Ureteral stents are commonly used after ureteroscopy to prevent complications from kidney stones, yet they can cause significant pain and urinary issues, which has led to calls for their omission in many cases.
  • - Guidelines support not using stents in uncomplicated surgeries, but over 80% of procedures still involve them, partly due to insufficient evidence about their impact on pain and patient outcomes.
  • - A new study is being conducted where patients randomly choose whether to have a stent or not, while those who refuse randomization will be observed based on the doctor's decision, aiming to gather real-world data on the effectiveness of stent omission.
View Article and Find Full Text PDF

A clinical comparative analysis using an optical tracking device versus conventional tracking device in the production of occlusal appliances.

J Prosthodont

December 2024

Advanced Graduate Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA.

Purpose: Optical tracking devices (OTDs) hold promise for enhancing patient-centered prostheses, but their efficacy remains underexplored. This clinical study aimed to comprehensively evaluate differences in static and dynamic occlusions among occlusal appliances fabricated using optical tracking, conventional tracking, and average articulator values (AAVs), providing insights into their efficacy in clinical and research-based practices.

Materials And Methods: Twelve dentate participants aged over 25 years, with Angle Class I and II occlusal relationships, were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!