A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Durable circulatory support with a paracorporeal device as an option for pediatric and adult heart failure patients. | LitMetric

Durable circulatory support with a paracorporeal device as an option for pediatric and adult heart failure patients.

J Thorac Cardiovasc Surg

Department of Cardiology, Sahlgrenska University Hospital, Gothenburg, Sweden; Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Transplant Institute, Sahlgrenska University Hospital, Gothenburg, Sweden.

Published: April 2021

Objectives: Not all patients in need of durable mechanical circulatory support are suitable for a continuous-flow left ventricular assist device. We describe patient populations who were treated with the paracorporeal EXCOR, including children with small body sizes, adolescents with complex congenital heart diseases, and adults with biventricular failure.

Methods: Information on clinical data, echocardiography, invasive hemodynamic measurements, and surgical procedures were collected retrospectively. Differences between various groups were compared.

Results: Between 2008 and 2018, a total of 50 patients (21 children and 29 adults) received an EXCOR as bridge to heart transplantation or myocardial recovery. The majority of patients had heart failure compatible with Interagency Registry for Mechanically Assisted Circulatory Support profile 1. At year 5, the overall survival probability for children was 90%, and for adults 75% (P = .3). After we pooled data from children and adults, the survival probability between patients supported by a biventricular assist device was similar to those treated with a left ventricular assist device/ right ventricular assist device (94% vs 75%, respectively, P = .2). Patients with dilated cardiomyopathy had a trend toward better survival than those with other heart failure etiologies (92% vs 70%, P = .05) and a greater survival free from stroke (92% vs 64%, P = .01). Pump house exchange was performed in nine patients due to chamber thrombosis (n = 7) and partial membrane rupture (n = 2). There were 14 cases of stroke in eleven patients.

Conclusions: Despite severe illness, patient survival on EXCOR was high, and the long-term overall survival probability following heart transplantation and recovery was advantageous. Treatment safety was satisfactory, although still hampered by thromboembolism, mechanical problems, and infections.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2020.04.163DOI Listing

Publication Analysis

Top Keywords

circulatory support
12
heart failure
12
ventricular assist
12
assist device
12
survival probability
12
left ventricular
8
children adults
8
heart transplantation
8
patients
7
heart
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!