Background: The effectiveness of microscopy of Gram-stained smear (GSS) for the detection of male urethral infection is debatable, especially in cases with low inflammation and no visible urethral discharge. This clinical study compared GSS samples collected with the conventional swab method and our new technique, the kissing slide method, together with polymerase chain reaction results to demonstrate the effectiveness of this new method in men with acute urethritis.
Methods: The study included 64 men who presented to the urology outpatient clinic with complaints of acute urethritis between October 2019 and January 2020. Two GSS samples were collected from each patient, first using the kissing slide method (applying the slide directly to the urethral mucosa), followed by the conventional method. The results were compared with polymerase chain reaction findings.
Results: The patients' mean age was 37.4 ± 7.8 years, and 68.7% had no visible urethral discharge on physical examination. At a GSS threshold of ≥5 polymorphonuclear leukocytes/high-power field, sensitivity values were 60% (95% confidence interval [CI], 42.32%-75.41%) for the kissing slide method and 23.33% (95% CI, 11.79%-40.93%) for the conventional method. At a threshold of ≥2 polymorphonuclear leukocytes/high-power field, sensitivity values with the kissing slide and conventional methods were 80% (95% CI, 62.69%-90.5%) and 50% (95% CI, 33.15%-66.85%) in all patients, and 66.67% (95% CI, 41.71%-84.82%) and 20% (95% CI, 7.047%-45.19%) in cases without visible urethral discharge, respectively.
Conclusion: The new kissing slide method is a noninvasive alternative method that may have better sensitivity than the conventional GSS sampling method in the diagnosis of male acute urethritis. Randomized studies are needed to verify these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OLQ.0000000000001228 | DOI Listing |
Gynecol Obstet Invest
November 2024
Department of Integrated Diagnostic and Surgical Sciences (DISC), University of Genoa, Genoa, Italy.
Background: Bowel endometriosis is one of the more severe manifestations of deep endometriosis; it may cause pain and intestinal symptoms. The noninvasive diagnosis of bowel endometriosis is of crucial importance in planning the management of patients affected by this condition.
Objectives: This review aims to describe how transvaginal ultrasonography (TVS) is performed in patients with suspicion of rectosigmoid endometriosis, the diagnostic performance, and the strengths and limitations of this technique.
Catheter Cardiovasc Interv
February 2023
Department of Cardiology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan.
Background: Kissing balloon inflation with distal guide wire recross can cause severe stent deformation depending on the stent link location with respect to the carina. The balloon-push technique, by which an inflated balloon is forced into the SB from the proximal main vessel (MV), is a feasible way to remove jailed struts without causing severe stent deformation.
Aims: We investigated the procedural success rate, patterns of jailed strut removal at side branch (SB) orifices, factors related to failure of jailed strut removal, and follow-up angiogram results of the balloon-push technique.
Sensors (Basel)
January 2023
School of Electrical Engineering, Tel-Aviv University (TAU), Tel Aviv 70100, Israel.
The present paper reports the outcomes of activities concerning a real-time SHM system for debonding flaw detection based on ground testing of an aircraft structural component as a basis for condition-based maintenance. In this application, a damage detection method unrelated to structural or load models is investigated. In the reported application, the system is applied for real-time detection of two flaws, kissing bond type, artificially deployed over a full-scale composite spar under the action of external bending loads.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
October 2021
Division of Cardiology, Department of Internal Medicine, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, South Korea.
Objectives: To evaluate the safety and technical utility of the short track sliding (STS) balloon catheter.
Background: An STS balloon catheter is designed to ensure a low profile at the shaft and perform distal anchoring using a single guidewire. However, its clinical practice with the STS balloon catheter has not been reported.
Eur J Obstet Gynecol Reprod Biol
June 2021
Department of Obstetrics and Gynecology, Clínica Universidad de Navarra, School of Medicine, University of Navarra, Pamplona, Spain.
Objectives: The aim of this study was to compare the accuracy of seven classical Machine Learning (ML) models trained with ultrasound (US) soft markers to raise suspicion of endometriotic bowel involvement.
Materials And Methods: Input data to the models was retrieved from a database of a previously published study on bowel endometriosis performed on 333 patients. The following models have been tested: k-nearest neighbors algorithm (k-NN), Naive Bayes, Neural Networks (NNET-neuralnet), Support Vector Machine (SVM), Decision Tree, Random Forest, and Logistic Regression.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!